41
CAUTION
If the cable gland are not mounted properly, the inverter can be
destroyed due to moisture and dust penetration. All the warranty
claim will be invalid.
Requirements
The AC cable is correctly connected.
The DC cable is correctly connected.
The country is set correctly.
7.1 Start the inverter
7.1.1 Touch control
Touch
Description
Single touch Switch display or Number +1
Double touch Enter or confirmation
Three touch Previous menu
Hold 5s
Confirm country setting or
number recover defaut value
7.1.2 Country/Area and Region setting
Information
Country/Area and Region setting
When the inverter start up,
the installer
need to select the right
country,if
the installer
don’t select any country, the inverter will
run under AS/NZS4777.2 as default for Australia & Region A,or
run under VDE0126-1-1 for other region after 30s.
When inverter powered on, OLED will light automatically. Once the PV power is
sufficient, OLED displays the following:
Press the touch key once a second to scroll through the different Country, showing on
the screen will constantly change.For example, if you want to choose Newzealand,
press the control key until the OLED display shows “Newzealand” as below: