EasyManua.ls Logo

Growatt MIC 2000 TL-X - Page 61

Growatt MIC 2000 TL-X
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
Max. DC voltage 500V
550V
Start voltage 50V 80V
Min. operating voltage 50V 65V
Nominal voltage 360V
MPP voltage range 50V-500V 65V-550V
No. of MPP trackers 1
No. of PV strings per MPP
trackers
1
Max. input current per MPP
trackers
13A
Max. short-circuit current
per
MPP trackers
16A
Output data(AC)
Rated output power 2000W 2500W 3000W 3300W
Rated apparent power 2000VA 2500VA 3000VA 3300VA
Max. AC apparent power 2000VA 2500VA 3000VA 3300VA
Nominal AC voltage/range* 230/180~280V
AC grid frequency/range 50-60Hz/44-55Hz;54-65Hz
Rated output current 8.7A 10.9A 13A 14.3A
Max. output current 9.5A 11.9A 14.3A 14.3A
Initial short-circuit AC current
8.7A 10.9A 13A 14.3A
Inrush current <10A
Max output fault current 66A
Max output overload
protection
16A
Backfeed current 0A
Power factor(@nominal
power)
>0.99
Adjustable power factor
0.8leading… 0.8lagging
THDi
<3%
AC grid connection type
Single phase
Overvoltage category PV:II AC:III Others:I
Efficiency
Max. efficiency 97.6% 97.6% 97.6% 97.6%
Euro-eta 97% 97% 97.1% 97.1%
Protection devices
DC reverse-polarity
protection
Integrated
DC switch Integrated
DC Surge protection Type II
Insulation resistance
monitoring
Integrated
AC surge protection Type III

Related product manuals