5655
MID
17KTL3-XH
MID
20KTL3-XH
MID
25KTL3-XH
MID
30KTL3-XH
Input data (DC)
Recommended Max. PV
power (for module STC)
34000W
40000W
50000W
60000W
Max. DC voltage
1100V
Start voltage
200V
Nominal voltage
600V
MPPT voltage range
160-1000V
No. of MPP trackers
2
3
No. of PV strings per
MPP tracker
2/2
2/2
2/2/2
2/2/2
Max. input current per
MPP tracker
32A/32A
32A/32A
32A/32A/32A
32A/32A/32A
Max. short-circuit
current per MPP tracker
40/40A
Backfeed current to PV
array
0A
DC Battery
Compatible
battery(only)
APX HV Battery
(5kWh~60kWh)
Operating voltage range
600 V ~ 980 V
Max. operating current
25A/25A
Max. discharge power
17000W
20000W
25000W
30000W
Max. charge power
15000W/30000KW
Qutput data (on-grid)
Nominal AC power
17000W
20000W
25000W
30000W
Max. AC apparent
power
18700VA
22000VA
27500VA
30000VA
Nominal AC
voltage/range
230/400V
AC grid frequency/range
50/60 Hz
45~55Hz/55-65 Hz
Max. output current
28.3A
33.3A
41.6A
45.5A
AC inrush current
60A
Max. output fault
current
74.1A
106.7A
Max. output overcurrent
Protection
74.1A
106.7A
Power factor(@nominal
power)
>0.99
Model
Specifications
MID
17KTL3-XH
MID
20KTL3-XH
MID
25KTL3-XH
MID
30KTL3-XH
THDi
<3%
AC grid connection type
3W+N+PE
Efficiency
Max. efficiency
98.00%
Euro-eta
97.50%
Output data (Backup)
Nominal output power
17000W
20000W
25000W
30000W
Max. apparent power
18700VA
22000VA
27500VA
30000VA
Nominal AC output
voltage
230V/400V
Nominal AC output
frequency
50Hz
Max. output current
25.8A
30.3A
37.9A
45.5A
Power factor
0.8 leading to 0.8 lagging
THDv
THDv2%@Rload, THDv5%@RCDload
DCV
300mV AVG
Switch time
<500ms
Protection devices
DC reverse-polarity
protection
YES
DC switch
YES
DC surge protection
YES
Insulation resistance
monitoring
YES
AC surge protection
YES
AC short-circuit
protection
YES
Grid monitoring
YES
Anti-islanding
protection
YES
Residual-current
monitoring unit
YES
String Fuse protection
NO
String monitoring
YES
AFCI protection
YES
Model