EasyManua.ls Logo

Growatt SPH TL BL-UP Series - Page 33

Growatt SPH TL BL-UP Series
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model
Specifications
Growatt
SPH3000
Growatt
SPH3600
Growatt
SPH4000
Growatt
SPH4600
Growatt
SPH5000
Growatt
SPH6000
AC connection
UPS output data
Max AC apparent
power
Rated AC output
voltage
Rated AC output
frequency
Starting mode
BAT data(DC)
Single
phase
Single
phase
Single
phase
Single
phase
Single
phase
Single
phase
6000W*5000W*4600W*4000W*3680W*3000W*
230Vac
50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz
230Vac 230Vac 230Vac 230Vac 230Vac
Setup Setup Setup Setup Setup Setup
42~59V 42~59V 42~59V 42~59V42~59V 42~59V
75A 75A 75A 75A 75A 75A
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
lithium /
Lead-acid
50~2000Ah 50~2000Ah 50~2000Ah 50~2000Ah 50~2000Ah 50~2000Ah
97.1%
96.8%
99.5% 99.5% 99.5% 99.5% 99.5% 99.5%
97.2%
96.9%
97.2%
96.9%
97.3%
97%
97.3%
97%
97.5%
97.1%
94%
yes yes yes yes yes yes
Battery voltage
range
Max charging
voltage
Max charging and
discharging
current
Max charging and
discharging
power
Type of battery
Capacity of
battery
Efficiency
Max. efficiency
Euro weighted
efficiency
MPPT efficiency
Protection devices
DC reverse polarity
protection
<3% <3% <3% <3% <3%
<3%
THDI
58V 58V 58V 58V 58V 58V
60
59
Model
Specifications
Growatt
SPH3000
Growatt
SPH3600
Growatt
SPH4000
Growatt
SPH4600
Growatt
SPH5000
Growatt
SPH6000
Output over
current protection
Output over
voltage protection-
varistor
Ground fault
monitoring
Grid monitoring
Integrated all -
pole sensitive
leakage current
monitoring unit
General Data
Dimensions (W / H
/ D) in mm
Weight
Noise emission
(typical)
Altitude
Self-Consumption
Inverter Topology
DC/DC topology
Cooling concept
Environmental
Protection Rating
Relative humidity
DC connection
AC connection
Features
Operating
temperature
range
BAT reverse
protection
yes
yes
yes
yes
yes
yes
450*565
*180
27KG
25°C ...
+60°Cwith
derating
above 45°C
25°C ...
+60°Cwith
derating
above 45°C
25°C ...
+60°Cwith
derating
above 45°C
25°C ...
+60°Cwith
derating
above 45°C
25°C ...
+60°Cwith
derating
above 45°C
25°C ...
+60°Cwith
derating
above 45°C
25 dB(A)
2000m2000m2000m2000m2000m2000m
< 7 W
transfor
merless
HF
transformer
HF
transformer
Natural
IP65
100%
MC4/H4
(opt)
connector connector connector connector connector connector
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
MC4/H4
(opt)
100% 100% 100% 100% 100%
IP65 IP65 IP65 IP65 IP65
Natural Natural Natural Natural Natural
HF
transformer
HF
transformer
HF
transformer
HF
transformer
transfor
merless
transfor
merless
transfor
merless
transfor
merless
transfor
merless
< 7 W < 7 W < 7 W < 7 W < 7 W
25 dB(A)25 dB(A)25 dB(A)25 dB(A)25 dB(A)
27KG 27KG 27KG 27KG 27KG
450*565
*180
450*565
*180
450*565
*180
450*565
*180
450*565
*180
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
1
1
1 1
1
1
Displacement
power factor,
configurable*
1 1 1 1 1 1
Phase factor at
rate power
0.8leading
0.8
lagging
0.8leading
0.8
lagging
0.8leading
0.8
lagging
0.8leading
0.8
lagging
0.8leading
0.8
lagging
0.8leading
0.8
lagging
AC overvoltage
category
Category III
3000W/
4000W/
10s *2
3600W/
4000W/
10s *2
3600W/
4000W/
10s *2
3600W/
4000W/
10s *2
3600W/
4000W/
10s *2
3600W/
4000W/
10s *2
Max battery
charging/
discharging
efficiency
94%94%94%94%94%