10. Technical data
10.1 Operating conditions
Supply voltage
- Pump 1 x 115 V, +10 % / -10 %, 60 Hz
Motor protection
The pump requires no external
motor protection.
Enclosure class
Indoor use only, IP42. CSA
enclosure type 2.
Insulation class F
Relative humidity Maximum 95 %
Max. outlet pressure 150 psi (10.34 bar)
Sound pressure level 43 dB (A)
Ambient temperature 34 to 104 °F (1 to 40 °C)
Inlet pressure
Liquid temperature Min. inlet pressure
167 °F (75 °C) 0.75 psi (0.05 bar)
194 °F (90 °C) 4.06 psi (0.28 bar)
230 °F (110 °C) 15.7 psi (1.08 bar)
Liquid temperature
36 °F (2 °C) to 230 °F (110 °C)
In domestic hot water systems, keep the liquid
temperature below 149 °F (65 °C) to eliminate the risk of
lime precipitation.
To avoid condensation in the control box and stator, the liquid
temperature must always be higher than the ambient temperature.
Ambient
temperature
[°F (°C)]
Min. liquid
temperature
[°F (°C)]
Max. liquid
temperature
[°F (°C)]
34 (1) 36 (2) 230 (110)
50 (10) 50 (10) 230 (110)
68 (20) 68 (20) 230 (110)
86 (30) 86 (30) 230 (110)
95 (35) 95 (35) 194 (90)
104 (40) 104 (40) 158 (70)
Approximate power usage
Minimum
2 W
Maximum 45 W
11. Disposing of the product
CAUTION
Magnetic field
Minor or moderate personal injury
Persons with pacemakers dismantling this product
must exercise care when handling the magnetic
materials embedded in the rotor.
This product or parts of it must be disposed of in an environmentally
sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company or
service center.
See also end-of-life information at www.grundfos.com/product-
recycling.
13
English (US)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos ALPHA 15-55 HWR-T and is the answer not in the manual?

Grundfos ALPHA 15-55 HWR-T Specifications

General IconGeneral
ModelALPHA 15-55 HWR-T
CategoryWater Pump
TypeCirculator Pump
Max. Operating Pressure145 psi
Frequency60 Hz
EEI0.20
Max Head (metric)5.5 m
Protection ClassIP42
MaterialCast Iron
ApplicationRecirculation
Port-to-Port Length6.5 inches
Max Flow Rate (metric)1.5 m³/h
Power SupplySingle-phase
Temperature Range36°F to 230°F
Liquid Temperature Range2°C to 110°C