Do you have a question about the Grundfos ALPHA2 and is the answer not in the manual?
Max Head | 8 m |
---|---|
Voltage | 230 V |
Frequency | 50/60 Hz |
Type | Circulator Pump |
Max. operating pressure | 10 bar |
Series | ALPHA2 |
Connection Type | Threaded |
Protection Class | IP42 |
Liquid Temperature Range | 2°C to 110°C |
Energy Efficiency Index | ≤ 0.23 |
Connection size | G 1 1/2 |
EEI | ≤ 0.23 |
Details the design and purpose of the ALPHA2 circulator pump.
Highlights key benefits like easy installation, comfort, and low energy consumption.
Specifies compatible heating system types for the ALPHA2 pump.
Defines acceptable liquids for pumping and liquids to avoid.
Defines the maximum permissible system pressure for the pump.
Specifies the maximum allowed relative air humidity for operation.
Indicates the pump's protection against solids and liquids (IP rating).
Details minimum inlet pressure requirements based on liquid temperature.
Provides instructions for physically mounting the pump in the system.
Explains the different possible positions for the pump's control box.
Details the procedure for rotating the pump's control box.
Guides on how to insulate the pump housing to reduce heat loss.
Identifies and describes the components of the pump's control panel.
Explains the function and information shown on the pump's digital display.
Explains the eight light fields that indicate the selected pump setting.
Describes the light indicator for the Automatic Night SetBack function.
Details how to activate or deactivate the Automatic Night SetBack feature.
Explains how to cycle through and select different pump settings.
Recommends pump settings based on different heating system types.
Explains the principles of proportional and constant pressure control modes.
Outlines the conditions and prerequisites for using Automatic Night SetBack.
Describes how the Automatic Night SetBack function operates and changes pump performance.
Explains the function of a bypass valve in heating systems.
Provides instructions for adjusting a manually operated bypass valve.
Details setting a pump with a thermostatically controlled bypass valve.
Specifies prerequisites before the pump can be safely started.
Guides on how to vent air from the pump itself.
Explains the process for venting air from the entire heating system.
Shows how different pump settings affect performance curves.
Lists all technical specifications, operating limits, and performance data.
Provides dimensional drawings and data for specific ALPHA2 models.
Provides dimensional drawings and data for specific ALPHA2 A models.
Explains how to read and interpret pump performance curves.
Details the standard conditions under which performance curves are generated.
Presents performance curves for the ALPHA2 XX-40 pump model.
Presents performance curves for the ALPHA2 XX-50 pump model.
Presents performance curves for the ALPHA2 XX-60 pump model.
Explains the information found on the pump's nameplate.
Provides a key to understanding the alphanumeric designation of pump types.