Page #13 background imageLoading...
Page #13 background image
English (GB)
13
* If you use an external supply source, there must
be a connection to GND.
Fig. 9 Connection terminals, CME pump
(optional for CRE, CRIE, CRNE, SPKE
and MTRE pumps)
TM05 3510 3512
3
15
8
26
23
25
24
7
B
Y
6
5
2
4
10
A
AI2
GDS RX
GDS TX
GND
GENIbus A
GENIbus B
+5 V
+24 V
+24 V
GND
GENIbus Y
GND
+5 V
DI1
AI1
DI3/OC1
+24 V*
+
+
+24 V*/5 V*
+24 V*
+5 V*
NC
C2
NO
NC
C1
NO
+24 V*
+
+
+24 V*/5 V*
+24 V*
+24 V*
OC
DI
GND
Terminal Type Function
NC
Normally
closed contact
Signal relay 1
(LIVE or PELV)
C1 Common
NO
Normally open
contact
NC
Normally
closed contact
Signal relay 2
(PELV only)
C2 Common
NO
Normally open
contact
10 DI3/OC1
Digital input/output,
configurable.
Open collector: Max.
24 V resistive or
inductive.
4AI1
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V /
0-10 V
2DI1
Digital input,
configurable
5+5 V
Supply to
potentiometer and
sensor
6 GND Ground
A GENIbus, A GENIbus, A (+)
Y GENIbus, Y GENIbus, GND
B GENIbus, B GENIbus, B (-)
3 GND Ground
15 +24 V Supply
8 +24 V Supply
26 +5 V
Supply to
potentiometer and
sensor
23 GND Ground
25 GDS TX
Grundfos Digital
Sensor output
24 GDS RX
Grundfos Digital
Sensor input
7AI2
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V /
0-10 V

Table of Contents

Other manuals for Grundfos CRIE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CRIE and is the answer not in the manual?

Grundfos CRIE Specifications

General IconGeneral
Frequency50/60 Hz
MaterialStainless Steel
Flow RateUp to 120 m³/h
Pumped LiquidClean, non-aggressive liquids
Voltage220-240 V / 380-415 V