EasyManuals Logo
Home>Grundfos>Water Pump>DMS 2

Grundfos DMS 2 User Manual

Grundfos DMS 2
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
10
4.2 Start/stop of pump
The pump can be started/stopped in two different
ways:
Locally on the pump control panel.
By switching on/off the electricity supply.
4.3 Priming/venting of pump
The pump control panel incorporates a button.
Press this button if the maximum pump capacity is
required over a short period, e.g. during start-up.
When the button is released, the pump automatically
returns to the previous operating mode.
During priming/venting, it is recommended to let the
pump run without a counter pressure or to loosen the
vent valve by giving it a 1/8 to 1/4 turn.
Note: When the buttons and are pressed
simultaneously, the pump can be set to run for a spe-
cific number of seconds at maximum capacity. The
remaining number of seconds will appear in the dis-
play. The maximum value is 300 seconds.
4.4 Indicator lights
The green and red indicator lights on the pump are
used for operating and fault indication.
The functions of the indicator lights appear from the
table below:
Condition
Green
LED
Red
LED
Display
Pump running On Off
Normal
indication
Set to stop Flashing Off
Normal
indication
Pump fault Off On EEPROM
Supply failure Off Off Off
Overheating Off On
MAX.
TEMP.
100%
100%

Other manuals for Grundfos DMS 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos DMS 2 and is the answer not in the manual?

Grundfos DMS 2 Specifications

General IconGeneral
BrandGrundfos
ModelDMS 2
CategoryWater Pump
LanguageEnglish

Related product manuals