P07.27
Type of the
current fault
0: No fault
1: Inverter unit U phase protection (OUt1)
2: Inverter unit V phase protection (OUt2)
3: Inverter unit W phase protection (OUt3)
4: ACC overcurrent (OC1)
5: DEC overcurrent (OC2)
6: Constant-speed overcurrent (OC3)
7: ACC overvoltage (OV1)
8: DEC overvoltage (OV2)
9: Constant-speed overvoltage (OV3)
10: Bus undervoltage fault (UV)
11: Motor overload (OL1)
12: The inverter overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
15: Rectifier module overheat (OH1)
16: Inverter module overheat (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor antotuning fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback disconnection fault (PIDE)
23: Brake unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
2631: Reserved
32: Short-to-ground fault 1 (ETH1)
33: Short-to-ground fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36: Underload fault (LL)
37: Hydraulic probe damage (tSF)
38: PV reverse connection fault (PINV)
39: PV overcurrent (PVOC)
40: PV overvoltage (PVOV)
41: PV undervoltage (PVLV)
Alarm:
Weak light alarm (A-LS)
Underload alarm (A-LL)
Full-water alarm (A-tF)
Water-empty alarm (A-tL)
P07.28
Type of the
last fault
P07.29
Type of the
last but one
fault
P07.30
Type of the
last but two
fault
P07.31
Type of the
last but three
fault
P07.32
Type of the
last but four
fault
P08 Group: Enhanced functions
P08.28
Number of
fault resets
010
5
P08.29
Automatic
fault reset
interval
0.13600.0s
10.0s