EasyManua.ls Logo

Grundfos IO 100 - CU 200 Control Unit Technical Data

Grundfos IO 100
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Technical data
SQFlex
CU 200 control unit
Voltage
30 - 300 VDC
90 - 240 VAC –10%/+6%, 50/60, PE.
Power consumption 5 W.
Current consumption Max. 130 mA.
Enclosure class IP 55 / NEMA 3R.
Ambient temperature In operation: –22°C to +140°F; during storage: –22°C to +140°F.
Relative air humidity 95%.
Pump cable
Max. length between CU 200 and pump: 660 feet.
Max. length between CU 200 and level switch: 1640 feet.
Back-up fuse Max.: 10 A.
Radio noise
The CU 200 complies with EMC Directive 89/336/EEC.
Approved according to standards EN 55 014 and 55 014-2.
Marking CE.
Weight 4.5 lb