7. Technical data
Maximum ambient temperature
35 or 55 °C. See the nameplate.
Liquid temperature
Domestic use: 0-35 °C or 0-60 °C. See the
nameplate.
Other use: 0-40 °C.
Maximum operating pressure
6 bar, 600 kPa.
Maximum flow rate
Maximum head
Maximum inlet pressure
Maximum suction lift
JPA, JPC: 8 m, including a pressure loss, at a liquid
temperature of 20 °C.
JPD: 27 m.
Pump type [m
3
/h]
JPA 3-42 / JPA 3-42 PT-H 3
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
4
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
4
JPA 5-61 / JPA 5-61 PT-V 5
JPA 8-62 / JPA 8-62 PT-V 8
JPA 12-41 12
JPA 12-51 12
JPC 3-42 / JPC 3-42 PT 3
JPC 4-47 / JPC 4-47 PT 4
JPC 4-54 / JPC 4-54 PT 4
JPC 5-48 5
JPD 4-47 PT 4
JPD 4-54 PT 4
JPD 5-61 PT 5
JPD 8-62 PT 8
Pump type [m]
JPA 3-42 / JPA 3-42 PT-H 42
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
47
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
54
JPA 5-61 / JPA 5-61 PT-V 61
JPA 8-62 / JPA 8-62 PT-V 62
JPA 12-41 41
JPA 12-51 51
JPC 3-42 / JPC 3-42 PT 42
JPC 4-47 / JPC 4-47 PT 47
JPC 4-54 / JPC 4-54 PT 54
JPC 5-48 48
JPD 4-47 PT 47
JPD 4-54 PT 54
JPD 5-61 PT 61
JPD 8-62 PT 62
Pump type [bar] [MPa]
JPA 3-42 / JPA 3-42 PT-H 3.8 0.38
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
3.3 0.33
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
2.6 0.26
JPA 5-61 / JPA 5-61 PT-V 1.9 0.19
JPA 8-62 / JPA 8-62 PT-V 1.8 0.18
JPA 12-41 3.9 0.39
JPA 12-51 2.9 0.29
JPC 3-42 / JPC 3-42 PT 1.8 0.18
JPC 4-47 / JPC 4-47 PT 1.3 0.13
JPC 4-54 / JPC 4-54 PT 0.6 0.06
JPC 5-48 1.2 0.12
JPD 4-47 PT 1.3 0.13
JPD 4-54 PT 0.6 0.06
JPD 5-61 PT 1.9 0.19
JPD 8-62 PT 1.8 0.18

Other manuals for Grundfos JPA Series

Related product manuals