6.4 Description of fault indications
If a fault occurs, the symbol will be visible, an audible alarm will be given by the buzzer and the fault code will be written by means of
the 14-segment characters in the display. To see the kind of fault, if it is automatically reset and the code is not longer visible, open the
fault log (see fig. 13). When you leave the fault log, the symbol will disappear.
The last 20 faults are stored in the fault log as fault codes. The meaning of the fault codes are described in the table below:
Fault
code
Meaning
Displayed
text
Flashing
symbols
Reset of
fault
indications
Description
Auto Man
F001
Phase sequence
failure
F001
(Only three-phase pumps)
The phase sequence between control board and power supply is
wrong. See fig. 14.
F002
One phase
missing
F002 ●●
(Only three-phase pumps)
One phase is missing.
F003 High liquid level F003 ●●The liquid level is high in relation to preset value.
F004 Sensor failure SENSOR - ●●Sensor signal out of range or lost.
F005
Overtemperature,
pump 1
TEMP ●●
Motor thermal switches connected to the controller will stop
pump 1 in case of overheating.
F006
Overtemperature,
pump 2
TEMP ●●
Motor thermal switches connected to the controller will stop
pump 2 in case of overheating.
F007
Overcurrent,
pump 1
F007
Pump 1 is stopped if an overcurrent is measured for a certain
period of time (blockage protection).
F008
Overcurrent,
pump 2
F008
Pump 2 is stopped if an overcurrent is measured for a certain
period of time (blockage protection).
F009
Undercurrent,
pump 1
F009 ●●
Pump 1 is stopped if an undercurrent is measured for a certain
period of time (dry running protection).
F010
Undercurrent,
pump 2
F010 ●●
Pump 2 is stopped if an undercurrent is measured for a certain
period of time (dry running protection).
F011
Operating time
exceeded, pump 1
F011 ●●
Pump 1 is stopped if normal operating time of the pump is
exceeded, e.g. due to venting problems of pump housing, closed
discharge valve (forgotten to open it after service/maintenance),
forgotten to switch back to automatic mode, if ON-OFF-AUTO
switch is set to "ON" for service/maintenance. A subsequent
emergency operation starts and stops the pump automatically
until the controller gets a regular stop signal from the sensor.
The controller then switches back to normal operation.
F012
Operating time
exceeded, pump 2
F012 ●●
Pump 2 is stopped if normal operating time of the pump is
exceeded, e.g. due to venting problems of pump housing, closed
discharge valve (forgotten to open it after service/maintenance),
forgotten to switch back to automatic mode, if ON-OFF-AUTO
switch is set to "ON" for service/maintenance. A subsequent
emergency operation starts and stops the pump automatically
until the controller gets a regular stop signal from the sensor.
The controller then switches back to normal operation.
F013 External fault EXT -
An external level switch can be connected to the controller to give
an alarm when basement outside the lifting station is flooded by
groundwater or water from burst water pipe.
F014 Battery failure BAT - ●●The battery is empty and must be replaced.
F015
Relay or contactor
does not open,
pump 1
RELAY
Pump 1 receives a signal to stop, but does not react.
This situation is detected by current measurement.
F016
Relay or contactor
does not close,
pump 1
RELAY
Pump 1 receives a signal to start, but does not react.
This situation is detected by current measurement.
F017
Relay or contactor
does not open,
pump 2
RELAY
Pump 2 receives a signal to stop, but does not react.
This situation is detected by current measurement.
F018
Relay or contactor
does not close,
pump 2
RELAY
Pump 2 receives a signal to start, but does not react.
This situation is detected by current measurement.