8
4.2 Electrical connection
Fig. 5 Position of terminals
Warning
To avoid the risk of electric shock or fire,
make sure that the power supply has been
cut off before connecting the equipment.
To avoid live voltage on the cabinet, make
sure the earth terminal is reliably
grounded.
Caution
To avoid arcing and fire, tighten all
terminals with the specified torque.
For distances (pump to inverter) exceeding
30 m, we recommend a reactor with
matching current ratings.
TM06 6530 1914
Terminal DescripƟon
L1
L2
L3
These terminals are the input cŽŶŶĞĐƟŽŶƐ for the power
supply.
DC-
DC+/R+
R-
DC bus terminals (DC- DC+)
and
Brake resistor terminals (R+ R-)
U/T1
V/T2
W/T3
These terminals are for motor cŽŶŶĞĐƟŽŶƐ
FILTER
AC power supply
PUMP
W/T3
V/T2
(V)
(U)
(W)
(PE)
U/T1 DC+/R+R+ DC- L3 L2 L1
(PE)
3
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
30
10
A
11
B
Standard I/O
Terminal Signal
1 +10 Vref Reference output
2
AI1+
Analogue input,
voltage or current
3
AI1-
Analogue input com-
mon
4
AI2+
Analogue input,
voltage or current
5
AI2-
Analogue input com-
mon
6
24Vout 24V aux. voltage
7
GND I/O ground
8
DI1 Digital input 1
9
DI2 Digital input 2
10
DI3 Digital input 3
11
CM
Common for DI1-DI6
*
* Can be isolated from ground see chap
12
24Vout 24V aux. voltage
13
GND I/O ground
14
DI4 Digital input 4
15
DI5 Digital input 5
16
DI6 Digital input 6
17
CM Common for DI1-DI6*
18
AO1+
Analogue output,
voltage or current
19
AO-/GND
Analogue output com-
mon
30 +24 Vin
24V auxiliary input
voltage
A RS485 Serial bus, ŶĞŐĂƟve
B RS485 Serial bus, ƉŽƐŝƟve
Reference
poteŶƟŽŵĞƚĞƌ 1...10 k
ё
Remote reference
4...20mA/0...10V
mA
100X
Terminal Description
L1
L2
L3
These terminal are the input connections
for the power supply.
DC-
DC+/R+
R-
DC bus terminal (DC- DC+)
and
Break resistor terminals (R+ R-)
U/T1
V/T2
W/T3
These terminal are for motor connections.
Pump
Filter
AC power supply
3~
Standard I/O
Terminal Signal
1 +10 Vref Reference output
2 AI1+
Analogue input,
voltage or current
3 AI1- Analogue input common
4 AI2+
Analogue input,
voltage or current
5 AI2- Analogue input common
6 24 Vout 24 V aux. voltage
7 GND I/O ground
8 DI1 Digital input 1
9 DI2 Digital input 2
10 DI3 Digital input 3
11 CM Common for DI1-DI6
12 24 Vout 24 V aux. voltage
13 GND I/O ground
14 DI4 Digital input 4
15 DI5 Digital input 5
16 DI6 Digital input 6
17 CM Common for DI1-DI6
18 AO1+ Analogue output, voltage or current
19 AO-/GND Analogue output common
30 +24 Vin 24 V auxiliary input voltage
A RS485 Serial bus, negative
B RS485 Serial bus, positive
Reference
potentiometer
1...10 kΩ
Remote reference
4...20mA / 0...10V