English (GB)
17
6. Disposal
This product or parts of it must be disposed of in an environmentally sound
way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company or service
workshop.
Max. cable length
Cable size
Max. cable length at 20 °C
[m]
AWG
Diameter
[mm]
Cross-
sectional area
[mm
2
]
Load
resistance
500R
Load
resistance
250R
17 1.15 1.04 8896 16309
18 1.02 0.82 7055 12934
19 0.91 0.65 5595 10257
20 0.81 0.52 4437 8134
21 0.72 0.41 3518 6451
22 0.64 0.33 2790 5116
23 0.57 0.26 2213 4057
24 0.51 0.20 1755 3217
25 0.45 0.16 1392 2551
26 0.40 0.13 1104 2023
Other data
Enclosure class IP20
Ambient temperature
During operation -20 °C to +50 °C (-4 °F to +122 °F)
During storage -20 °C to +70 °C (-4 °F to +158 °F)
During transport -20 °C to +70 °C (-4 °F to +158 °F)
SI 010 CNV must not be exposed to direct sunlight during
operation.