30
Instruction GS 1010
GS Engineering B.V.
manufacturer hydraulic sweepers
To empty the collector box, follow this simple procedure: take hold of the handle of
the collector box (the handle that points towards the push bar) and pull towards you.
(see Illustration 7)
The machine must be turned off when emptying the collector box.
Illustration 7
If you want to remove the collector box, you can lift it from the mounting supports.
Take hold again of both handles of the collector box and pull them out.
If the machine is used without the collector box, the mounting
supports must be removed. Failure to remove them could result
in accidents.
When adjusting the height of the collector box, you also have to
adjust the height of the brushes. Always observe a clearance of
+/- 20 mm (measured from the surface to be swept till the lower
side of the collector box).