GDM-8245 User Manual
50
TRUE RMS AC, AC+DC VOLTAGE
Accuracy Between 2% of range and full range.
Range 20Hz-
45Hz
45Hz-
1kHz
1kHz-
2kHz
500mV 1%+15 0.5%+15 0.5%+15
5V 1%+15 0.5%+15 0.5%+15
50V 1%+15 0.5%+15 0.5%+15
500V 1%+15 0.5%+15 --------
1000V 1%+15 0.5%+15 --------
Range 2kHz-
10kHz
10kHz-
20kHz
20kHz-
50kHz
500mV 1%+15 2%+30 5%+30
5V 1%+15 2%+30 5%+30
50V 1%+15 2%+30 5%+30
500V -------- -------- --------
1000V -------- -------- --------
500mV 10uV
10MΩ
5V 100uV
11.1 MΩ
50V 1mV
10.1MΩ
500V 10mV
10MΩ
1000V 100mV
10MΩ
Input Impedance
Approx. 10MΩ in parallel with < 100pF, all ranges.
Maximum Input 450V dc or peak ac continuous on 500mV range.
1000Vrms on other range.
Crest Factor Range 3.0 at full scale.
dBm (ref 600Ω)
63.8dBm ~ -97.7dBm.
When the input exceeds the full scale of the selected range, the display will
indicate over-range: “—OL—“.