GDS-806/810/820/840 Programming Manual
49
:SYSTem:UNLock
The front panel keyboards and knobs of the oscilloscope will be disabled after any
one of the remote control command received. Use this command in order to
re-activate the front panel keyboards and knobs.
Syntax
:SYSTem:UNLock
:TEMPlate<X>:DOWNload? (Available for firmware 2.0 and above only)
Download the user-selected template.
Syntax
:TEMPlate1:DOWNload?
Arguments
<X>Specify the template number (1|100)
Returns
Format:
The string of data is following.
# Data size digit Data
size
Package
type
Template
number
Position Text
string
Reserved Check
sum
Template
data
#: Begin of data string.
Data size digit: Indicate the digits of following data string amount (1 digit), The
value is ‘3’ in ASCII code.
Data size: The amount of current data string (3 digits). The value is “548” in
ASCII code.
Package type: The GO/NO-GO template package type (1 bytes). The value is
0x03 in hex.