EasyManua.ls Logo

GYS GYSMI 80P - User Manual

GYS GYSMI 80P
56 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
73505_V18_10/01/2022
FR
EN
DE
ES
RU
NL
IT
02-07 / 50-56
08-13 / 50-56
14-19 / 50-56
20-25 / 50-56
26-31 / 50-56
32-37 / 50-56
38-43 / 50-56
GYSMI 80P - 130P
160P - 200P
www.gys.fr
MADE IN FRANCE
Find more languages of user manuals on our website
Poste à souder MMA
MMA welding machine
E-Hand-Schweißgerät
Equipo de soldadura MMA
Сварочный аппарат ММА
MMA Lasapparaat
Dispositivo di saldatura MMA
Stanowisko do spawania MMA
PL
44-49 / 50-56

Questions and Answers

  • J
    Jason BennettAug 10, 2025
    What to do if I feel tingling when touching my GYS GYSMI 80P Welding System?
    • L
      Logan OrtizAug 10, 2025
      If you are feeling a tingling sensation when touching the body of your GYS Welding System, it indicates an undervoltage issue, likely caused by a faulty earth contact. Check the plug and the earth connection of your installation.
  • J
    Jason PowellAug 16, 2025
    What to do if my GYS GYSMI 80P Welding System green indicator is on but it doesn't weld?
    • N
      nfitzgeraldAug 16, 2025
      If the green indicator is on but your GYS Welding System isn't welding, there may be a fault with the earth clamp or cable connection. Check all connections to ensure they are properly secured.
  • B
    Brian KnightAug 22, 2025
    How to fix GYS Welding System when both indicators are on but there is no current?
    • G
      Gregory BruceAug 22, 2025
      If both indicators are illuminated on your GYS Welding System, but the machine isn't delivering any current, it's likely that the thermal protection has activated. Wait for the cooling cycle to complete.
  • T
    Todd HarperAug 28, 2025
    What to do if the green indicator is on, but my GYS GYSMI 80P Welding System does not weld?
    • A
      Ashley MartinezAug 28, 2025
      If the green indicator is on but your GYS Welding System isn't welding, there may be a fault with the earth clamp or cable connection. Inspect the connections to ensure they are properly secured.
  • C
    chad38Sep 3, 2025
    How to fix GYS Welding System when 2 indicators are on, but there is no current?
    • R
      Regina RobinsonSep 3, 2025
      If both indicators are illuminated on your GYS Welding System and the machine isn't delivering current, it's likely that the thermal protection has activated. Wait for the cooling cycle to complete before resuming use.

Summary

Safety Rules and Precautions

General Safety Guidelines

Read and understand safety recommendations before using or servicing. No unauthorized servicing.

Environmental and Personal Protection

Use in protected areas, wear protective gear for welding hazards like arc rays, heat, and fumes.

Welding Hazards and Risks

Covers hazards from fumes, gas, fire, explosions, and electrical safety, including gas bottle handling.

Electromagnetic Interference (EMI) & Assessment

Understand EMF effects on medical implants and assess the welding area for potential electromagnetic problems.

Emissions Reduction & Handling

Methods to reduce emissions, transport, transit, and installation requirements for the welding machine.

Maintenance, Operation, and Setup

Maintenance and Product Operation

Procedures for maintenance, installation, product operation, and setup.

Power Supply & Welding Modes

Details on power supply, generator connection, MMA, and TIG welding modes.

Troubleshooting and Warranty

Troubleshooting Common Issues

Guide to identify and resolve common symptoms, causes, and remedies for operational problems.

Warranty Information

Covers warranty terms, exclusions, and procedures for claims.

Parts and Specifications

Spare Parts and Electrical Diagram

List of replacement parts and the electrical schematic for the welding machine.

Machine Interface Details

Descriptions of interface elements like potentiometer, indicators, and connectors for different models.

Technical Specifications

Primary and secondary electrical specifications, performance data, and duty cycles.

Operating Conditions and Dimensions

Operating/storage temperatures, IP rating, insulation class, physical dimensions, and weight.

Icon Guide and European Compliance

Explanation of manual icons and details on CE compliance.

Regulatory Compliance and Standards

Information on UK CA, EAC compliance, and specific welding standards like EN60974.

GYS GYSMI 80P Specifications

General IconGeneral
Input Voltage230 V
Output Current Range10 - 80 A
Input Frequency50/60 Hz
Max Input Current16 A
Efficiency85 %
Protection ClassIP21
Welding ProcessMMA
Electrode Diameter1.6 mm

Related product manuals