53
1::100 0001-0000-0047 N/A Vsi1 STALE D 232
4::400 0002-0000-0047 N/A Vsi2 REACH D 3
FE80::201:FF:FE00:0 0001-0000-0000 N/A Vsi1 STALE D 237
FE80::201:FF:FE00:47 0001-0000-0047 N/A Vsi1 STALE D 222
FE80::202:FF:FE00:0 0002-0000-0000 N/A Vsi2 STALE D 345
# Verify that Switch B has created FIB entries for the user terminals.
[SwitchB] display ipv6 fib 1::100
Destination count: 1 FIB entry count: 1
Flag:
U:Useable G:Gateway H:Host B:Blackhole D:Dynamic S:Static
R:Relay F:FRR
Destination: 1::100 Prefix length: 128
Nexthop : 1::100 Flags: UH
Time stamp : 0x21 Label: Null
Interface : Vsi1 Token: Invalid
[SwitchB] display ipv6 fib 4::400
Destination count: 1 FIB entry count: 1
Flag:
U:Useable G:Gateway H:Host B:Blackhole D:Dynamic S:Static
R:Relay F:FRR
Destination: 4:: Prefix length: 64
Nexthop : :: Flags: U
Time stamp : 0x19 Label: Null
Interface : Vsi2 Token: Invalid
3. Verify the network connectivity for the user terminals:
# Verify that Terminal 1 and Terminal 2 can ping each other. (Details not shown.)
# Verify that Terminal 1, Terminal 2, and VLAN-interface 20 (3::300) on Switch E can ping each
other. (Details not shown.)