H3C S5500-EI Series Ethernet Switches
Quick Start
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-08225N-20071215-C-1.01

Table of Contents

Other manuals for H3C S5500-EI Series

Questions and Answers

  • P
    Phillip McintyreAug 9, 2025
    What to do if H3C S5500-EI Switch AC input fails?
    • J
      Judith AtkinsAug 9, 2025
      If you experience an AC input failure with your H3C Switch, first check whether the power cord is properly connected to the switch. Next, verify that the external AC power supply system is functioning correctly. Lastly, ensure the switch's operating temperature is normal and that the power supply has adequate ventilation.
  • E
    Emily RodgersAug 14, 2025
    What to do if H3C S5500-EI RPS input fails?
    • R
      Richard MontgomeryAug 14, 2025
      If the RPS input fails on your H3C switch, verify that the switch is securely connected to the external RPS power supply. Then, check to ensure the external RPS power supply is working correctly. Finally, confirm that the switch's operating temperature is within the normal range and that the power supply has good ventilation.
  • D
    Denise HudsonAug 19, 2025
    How to fix H3C S5500-EI Switch software loading failure?
    • K
      Kevin SanchezAug 19, 2025
      To resolve a software loading failure on your H3C switch, first check the physical port connections and reconnect them correctly if needed, then restart the loading procedure. Also, review the loading procedure information displayed on the HyperTerminal for any input errors and correct them before restarting. If problems persist, it is recommended to contact your agent for assistance.
  • K
    katrina70Aug 25, 2025
    What to do if I forgot the H3C S5500-EI Switch user password?
    • A
      andrewmolinaAug 25, 2025
      If you've forgotten the user password for your H3C Switch, enter the Boot Menu, select option 7, and then restart the switch. After the switch restarts, the user password will be removed.
  • B
    Brenda MillerAug 29, 2025
    What to do if H3C S5500-EI Switch configuration system fails and there is no terminal display?
    • L
      lisa30Aug 29, 2025
      If the configuration system fails on your H3C Switch and there is no terminal display, check that the power supply is working correctly. Also, verify that the console cable is properly connected.
  • J
    Jennifer MossSep 3, 2025
    What to do if H3C S5500-EI configuration system fails with illegible terminal display?
    • L
      Louis JordanSep 3, 2025
      If the configuration system fails on your H3C Switch and the terminal display is illegible, check that the terminal parameter settings are correct. Ensure the baud rate is 9,600, parity is set to none, flow control is set to none, and terminal emulation is VT100.

H3C S5500-EI Series Specifications

General IconGeneral
ModelH3C S5500-EI Series
MAC Address Table16K
Jumbo FrameUp to 9216 bytes
Operating Temperature0°C to 45°C
Operating Humidity10% to 90% (non-condensing)
Storage Temperature-40°C to 70°C
Storage Humidity5% to 95% (non-condensing)
ManagedYes
LayerLayer 3
VLAN supportYes
Ports24/48 x 10/100/1000BASE-T
Power SupplyAC 100-240V, 50/60Hz
Dimensions (W x D x H)440 x 44 mm
Switch TypeManaged Layer 2/3 Switch
VLANs4094
PoE SupportOptional (PoE and non-PoE models available)

Related product manuals