66
Figure 117 LSI RAID management screen
Switching the drive state
The storage controller supports the following drive states:
Unconfigured Good—The drive is normal and can be used for RAID array or hot backup
configuration.
Unconfigured Bad—The drive is faulty or has RAID array information remaining on it. If the
drive is faulty, replace the drive. If the drive has RAID array information remaining on it, clear
the information.
JBOD—Just a Bunch Of Drives. The drive is a passthrough drive and does not support RAID
configuration.
To switch from Unconfigured Bad state to Unconfigured Good state:
1. On the PD Mgmt screen as shown in Figure 118, select the target drive and press F2.
Figure 118 Selecting the target drive
2. On the screen as shown in Figure 119, select Make unconfigured good and press Enter.