EasyManuals Logo

H3C UniServer R4900 G5 User Manual

H3C UniServer R4900 G5
401 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
1
Configuring an NVMe VROC module
This chapter describes configuring the NVMe VROC module on a rack server, blade server, or
compute module.
About the NVMe VROC module
Intel
®
Virtual RAID on CPU (Intel
®
VROC) is an upper-layer RAID solution specifically designed for
NVMe drives that are directly connected to the CPU. VROC NVMe RAID is available only when an
NVMe VROC module is installed.
The NVMe VROC module has a corresponding connector on the system board or main board. For
more information about the NVMe VROC module connector, see the user guide for the server.
NVMe VROC module can manage NVMe U.2 SSDs and NVMe M.2 SSDs. If NVMe M.2 SSDs are
installed on a RAID-MARVELL-SANTACRUZ-LP-2i storage controller, the NVMe M.2 SSDs are
managed exclusively by the controller.
Features
NVMe VROC module specifications
Table 1 shows the specifications of NVMe VROC modules supported by the server. For more
information, contact Technical Support.
Table 1 NVMe VROC module specifications
Model Description RAID levels
N/A
No NVMe VROC
module installed
Intel NVMe drives P3608, P4608, and P4618: RAID 0.
Other NVMe drives: RAID not supported. Each drive
acts as a passthrough drive.
NOTE:
Intel NVMe drives P3608, P4608, and P4618 are not
supported by H3C servers.
NVMe-VROC-Key-i
Intel
®
VROC Intel
®
Edition
Intel NVMe drives: 0, 1, 5, 10
Other NVMe drives: RAID not supported. Each drive
acts as a passthrough drive.
NVMe-VROC-Key-S
Intel
®
VROC
Standard Edition
0, 1, 10
NVMe-VROC-Key-P
Intel
®
VROC
Premium Edition
0, 1, 5, 10
RAID levels
The supported RAID levels vary by NVMe VROC module model. For more information, see H3C
Servers Storage Controllers Technical Specifications.
Table 2 shows the minimum number of drives required by each RAID level and the maximum
number of failed drives supported by each RAID level. For more information about RAID levels, see
"Appendix B RAID arrays and fault tolerance."

Other manuals for H3C UniServer R4900 G5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R4900 G5 and is the answer not in the manual?

H3C UniServer R4900 G5 Specifications

General IconGeneral
BrandH3C
ModelUniServer R4900 G5
CategoryServer
LanguageEnglish

Related product manuals