PARAMETERS
June 1999
96-8000
50% RPD KBD When (1) the control will support the new style keyboards with the
50% rapid traverse key. For controls without a 50% rapid keypad set
this bit to (0).
FRONT DOOR When enabled the control will look for an additional door switch and
will generate an operator message.
TC Z NO HOME In Horizontal mills only. This bit prevents Z-axis motion to machine
zero prior to a tool change.
M36 AUTO MOT In Horizontal only. When set to (1), an M36 rotates the A-axis after
the PART READY button is pressed.
AUX AXIS TC In Horizontal mills only. When enabled, means the tool changer
carousel is driven by an aux. axis.
SPIGOT KEY INV This bit controls the direction the spigot moves when the Coolant Up
and Coolant Down buttons are pressed. Changing this bit reverses the
direction the spigot moves when the buttons are pressed. It has no
effect on the direction the spigot moves when commanded by the M34
and M35 codes.
T SUBROUTINE Reserved for future use.
SPIN Y ENCDR For Lathe only. When enabled, spindle encoder input is to the Y-axis.
REV CONVEYOR Reverses the direction of the chip conveyor.
M27-M28 CONVYR Usually the chip conveyor motor and direction relays are attached to
the user relays M21 and M22. When this bit is set, the control
expects to see the conveyor hooked up to M27 and M28.
GREEN BEACON When (1) user relay M25 is used to flash a beacon. If the control is in
a reset state, the beacon will be off. If the control is running normally,
the beacon will be steadily on. If the control is in a M00, M01, M02,
M30 feedhold, or single block state, then the beacon will flash.
RED BEACON When (1) user relay M26 is used to flash a beacon. The beacon
flashes if the control is experiencing an alarm or emergency stop
condition.
CONVY DR OVRD When (1) the conveyor will continue to run with the door open. When
(0) the conveyor will stop when the door is open, but will resume when
the door is closed. For safety it is recommended that the bit be set to
(0).
DSBL CLNT IN If set to 1 low coolant input will not be used.
DSC INP PR Discrete pallet rotate/part ready; inputs enabled if set to 1.
RMT TOOLS RLS If set to 1, allows use of remote tool release button on spindle head.
FLOPPY ENABL If set to 1, enables the optional floppy drive.
TCR KEYPAD If set to 1, enables tool changer restore button on keypad.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haas VF-4 and is the answer not in the manual?

Haas VF-4 Specifications

General IconGeneral
CategoryCNC Vertical Machining Center
Z Axis Travel25 in (635 mm)
Spindle Power30 hp (22.4 kW)
Spindle TaperBT-40
Spindle MotorVector drive AC motor

Related product manuals