REQUIRED REAGENTS AND APPARATUS
Cat. No.
Ammonia Nitrogen Reagent Set for 10-mL samples (100 tests)..................................26680-00
Includes: (2) 26531-99, (2) 26532-99
Quantity Required
Description Per Test Unit Cat. No.
Ammonia Cyanurate Reagent Powder Pillows...... 2 pillows...............100/pkg ..........26531-99
Ammonia Salicylate Reagent Powder Pillows....... 2 pillows...............100/pkg ..........26532-99
Sample Cell, 10-20-25 mL, w/ cap ...............................2.........................6/pkg..........24019-06
OPTIONAL REAGENTS
Ammonia Nitrogen Standard Solution, 10 mg/L as NH
3
-N ................. 500 mL ..............153-49
Ammonia Nitrogen, PourRite Ampules, 50 mg/L as NH
3
-N, 2 mL.......20/pkg..........14791-20
Cylinder, graduated, mixing, 25 mL ...........................................................each..........20886-40
Sodium Hydroxide Standard Solution, 1.0 N.............................. 100 mL MDB............1045-32
Sodium Hydroxide Standard Solution, 5.0 N...............................50 mL SCDB............2450-26
Sodium Thiosulfate Standard Solution, 0.1 N............................. 100 mL MDB ..............323-32
Sulfide Inhibitor Reagent Powder Pillows............................................100/pkg............2418-99
Sulfuric Acid, concentrated, ACS......................................................... 500 mL..............979-49
Sulfuric Acid Standard Solution, 1.0 N....................................... 100 mL MDB ............1270-32
Water, deionized........................................................................................... 4 L..............272-56
OPTIONAL APPARATUS
Cylinder, graduated, polypropylene, 500 mL..............................................each ............1081-49
Distillation Heater and Support Apparatus, 115 V......................................each ..........22744-00
Distillation Heater and Support Apparatus, 230 V .....................................each ..........22744-02
Distillation Set, General Purpose ................................................................each..........22653-00
Filter Paper, folded, 12.5 cm........................................................................100............1894-57
Flask, Erlenmeyer, polypropylene, 500 mL................................................each ............1082-49
Flask, volumetric, Class A, 100 mL............................................................each..........14574-42
Funnel, poly, 65 mm....................................................................................each............1083-67
pH Meter, sens
ion
1, portable, with electrode...........................................each ..........51700-10
Pipet Filler, safety bulb ...............................................................................each ..........14651-00
Pipet, TenSette, 0.1 to 1.0 mL.....................................................................each..........19700-01
Pipet Tips, for 19700-01 TenSette Pipet .................................................50/pkg ..........21856-96
Pipet Tips, for 19700-01 TenSette Pipet ............................................1000/pkg..........21856-28
Pipet, volumetric, Class A, 2.0 mL.............................................................each ..........14515-36
PourRite Ampule Breaker Kit.....................................................................each ..........24846-00
Thermometer, –20 to 110 °C.......................................................................each ..........26357-02
For Technical Assistance, Price and Ordering
In the U.S.A.—Call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
NITROGEN, AMMONIA, continued