EasyManua.ls Logo

Hach DR/850 - Page 346

Hach DR/850
460 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
346
REQUIRED REAGENTS
Phosphonates Reagent Set (100 tests) ..........................................................................24297-00
Includes: (2) 21060-69, (1) 20847-69
Quantity Required
Description Per Test Unit Cat. No
PhosVer 3 Phosphate Reagent Powder Pillows .... 2 pillows ............100/pkg.............21060-69
Potassium Persulfate Pillow for Phosphonate ........ 1 pillow ............100/pkg .............20847-69
Water, deionized..........................................................varies ................... 4 L.................272-56
REQUIRED APPARATUS
Cylinder, mixing, graduated, 50 mL...................................1 ..................each ...............1896-41
Goggles, UV safety.............................................................1 ..................each............. 21134-00
Pipet, serological, 25 mL....................................................1 ..................each...............2066-40
Pipet Filler, safety bulb.......................................................1 ..................each.............14651-00
Sample Cell, 10-20-25 mL, w/cap......................................2 ................6/pkg .............24019-06
UV Lamp with power supply, 115 V, with goggles............1 ..................each .............20828-00
OR
UV Lamp with power supply, 230 V..................................1 ..................each.............20828-02
OPTIONAL REAGENTS
Hydrochloric Acid, 6.0 N (1:1).......................................................... 500 mL .................884-49
Sulfuric Acid, ACS............................................................................ 500 mL .................979-49
OPTIONAL APPARATUS
pH Paper, 1 to 11 pH units.............................................................5 rolls/pkg .................391-33
Pipet, serological, 2 mL...........................................................................each.................532-36
Pipet, TenSette, 1-10 mL .........................................................................each .............19700-10
Pipet Tips, for 19700-10 Tensette Pipet...............................................50/pkg .............21997-96
Thermometer, -20 to 110 °C, Non-Mercury ............................................each ...............1877-01
For Technical Assistance, Price and Ordering
In the U.S.A. call 800-227-4224
Outside the U.S.A.—Contact the Hach office or distributor serving you.
PHOSPHONATES, continued

Table of Contents

Other manuals for Hach DR/850

Related product manuals