Polymetron Conductivity
Sensors
02/2017, Edition 3
User Manual
Manuel d'utilisation
Manual del usuario
Manual do usuário
用户手册
取扱説明書
사용
설명서
คู่มือผู้ใช้

Table of Contents

Questions and Answers

  • R
    richarddouglasAug 19, 2025
    What to do if Hach Accessories show 'SENSOR MISSING'?
    • J
      John CollinsAug 19, 2025
      If the Hach Accessories display 'SENSOR MISSING', examine the wiring and connections for both the sensor and the module. Ensure that the terminal block is fully inserted into the module.
  • D
    Dustin GuerreroAug 21, 2025
    What to do if Hach Polymetron show 'NOT CALIBRATED'?
    • R
      Raymond DawsonAug 21, 2025
      If the Hach Accessories display 'NOT CALIBRATED', you should calibrate the sensor.
  • R
    Ross TurnerAug 23, 2025
    What does it mean when Hach Accessories show 'CAL OVERDUE'?
    • M
      Matthew ChangAug 23, 2025
      When the Hach Accessories display 'CAL OVERDUE', it means the sensor needs calibration. Calibrate the sensor.
  • A
    Amy GillespieAug 26, 2025
    What to do if Hach Polymetron Accessories show 'REPLACE SENSOR'?
    • C
      Courtney BarnettAug 26, 2025
      If the Hach Accessories display 'REPLACE SENSOR', calibrate the sensor with a reference solution and reset the sensor days. If the calibration fails, further assistance is needed.
  • M
    mccartykellyAug 27, 2025
    What does it mean when Hach Polymetron display 'CAL IN PROGRESS'?
    • K
      Kelly ConleyAug 28, 2025
      When Hach Accessories display 'CAL IN PROGRESS', return to calibration.
  • J
    Joseph RussoAug 30, 2025
    What to do if Hach Polymetron show 'ADC FAILURE'?
    • R
      Renee RobinsonAug 30, 2025
      If the Hach Accessories display 'ADC FAILURE', ensure that the sensor module is fully inserted into the controller connector. If the issue persists, replace the sensor module.
  • D
    Donna MolinaSep 1, 2025
    What to do if Hach Polymetron Accessories display 'SENS OUT RANGE'?
    • S
      Steven McgeeSep 1, 2025
      If the Hach Accessories display 'SENS OUT RANGE', make sure that the sensor is configured for the correct cell constant.
  • L
    Leah CarrSep 3, 2025
    What to do if Hach Polymetron show 'MEAS TOO HIGH'?
    • L
      Laura CoxSep 3, 2025
      If the Hach Accessories display 'MEAS TOO HIGH', make sure that the sensor is configured for the correct cell constant.
  • M
    Matthew TurnerSep 5, 2025
    What to do if Hach Polymetron show 'MEAS TOO LOW'?
    • M
      Michael WashingtonSep 5, 2025
      If the Hach Accessories display 'MEAS TOO LOW', ensure that the sensor is configured for the correct cell constant.
  • J
    Joshua FrancoSep 7, 2025
    Why do Hach Accessories show 'ZERO TOO HIGH'?
    • B
      ballardannaSep 7, 2025
      If the Hach Accessories display 'ZERO TOO HIGH', make sure that the sensor is held in air during zero calibration and is not located near radio frequency or electromagnetic interference. Also, make sure that the cable is shielded by metal conduit.

Summary

Specifications

General Information

Safety Information

Use of Hazard Information

Defines DANGER, WARNING, CAUTION levels and their implications for user safety.

Precautionary Labels

Explains safety alert symbols, ESD symbols, and disposal markings for safe operation.

Product Overview

Installation

Mounting

Details safe installation and removal procedures for sensors, emphasizing trained personnel and safety.

Connect the Sensor to the Module

Operation

User Navigation

Guides users on navigating the controller's interface for sensor setup and operation.

Configure the Sensor

Explains how to set up the sensor, including name, serial number, and measurement units.

Adjust T-Factor for Non-Standard Cable Lengths

Describes calculating and applying a T-factor to correct temperature measurements for non-standard cable lengths.

Calibrate the Sensor

About Sensor Calibration

Information regarding sensor calibration and its impact on data logging.

Zero Calibration Procedure

Step-by-step guide for performing zero calibration to define the sensor's zero point.

Calibration with a Reference Solution

Instructions for calibrating the sensor using a reference solution for accurate readings.

Calibration with the Process Sample

Procedures for calibrating the sensor using a sample from the process itself.

Temperature Calibration

Details on calibrating the temperature measurement for increased accuracy.

Exit Calibration Procedure

Options for exiting the calibration process, including quitting or returning.

Change Calibration Options

How to configure calibration reminders and operator ID settings.

Reset Calibration Options

Restores calibration settings to factory defaults.

Maintenance

Clean the Sensor

Step-by-step instructions for cleaning the conductivity sensor.

Modbus Registers

Information source for Modbus registers used for network communication.

Troubleshooting

Intermittent Data

Explains intermittent data occurrences during calibration.

Test the Conductivity Sensor

Guide to testing sensor resistance to diagnose calibration failures.

Sensor Diagnostic and Test Menu

Accessing and using the diagnostic menu for sensor information and status.

Error List

Lists common sensor errors and their potential resolutions.

Warning List for Sensors

Details sensor warnings, their causes, and how to address them.

Event List for Sensors

Lists significant events related to sensor configuration and operation.

Replacement Parts and Accessories

Consumables

Lists consumable items such as conductivity reference solutions and their item numbers.

Parts and Accessories

Lists replacement parts like cables, chambers, gaskets, and mounting kits with item numbers.