EasyManua.ls Logo

Hach TSS sc - User Manual

Hach TSS sc
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DOC023.52.90154
TSS sc
TSS W sc
TSS HT sc
TSS VARI sc
TSS XL sc
TSS TITANIUM2 sc
TSS TITANIUM7 sc
User Manual
09/2018, Edition 3

Table of Contents

Questions and Answers

  • M
    Mary McbrideAug 3, 2025
    What to do if Hach Test Equipment shows 'MEAS OVERRANGE'?
    • H
      hmathewsAug 3, 2025
      If the Hach Test Equipment shows 'MEAS OVERRANGE', it indicates that the measurement range has been exceeded, the signals are too small, or the probe can no longer measure the concentration. If this error occurs frequently, consider finding another installation location.
  • J
    Jacqueline PetersonAug 13, 2025
    What does 'ZERO' mean on Hach TSS sc?
    • J
      John NormanAug 13, 2025
      If the Hach Test Equipment displays 'ZERO', it means the calibration is too close to the zero point. To fix this, calibrate again, but this time use a higher concentration.
  • C
    Connie GeorgeAug 23, 2025
    How to fix 'REPLACE PROFILE' error on Hach Test Equipment?
    • A
      Adrian TorresAug 23, 2025
      If the Hach Test Equipment displays 'REPLACE PROFILE', it indicates that the counter is at zero. You should replace the wiper profile and then reset the counter.

Summary

Technical Data

1.1 Dimensions

Details the physical dimensions of the sensor and installation options.

Detailed Dimensions Diagram

Illustrates the physical dimensions of different sensor models with diagrams.

General Information

Safety Information

Provides essential safety precautions and hazard notices for operating the equipment.

Hazard Notices Explanation

Explains the meaning of danger, warning, caution, and notice symbols used in the manual.

Areas of Application Overview

Details the types of sludges and media the sensors are suitable for.

TSS sc;TSS W sc Application Range

Specific application range for TSS sc and TSS W sc sensors.

TSS HT sc Application Range

Specific application range for TSS HT sc sensors, including high temperatures.

TSS VARI sc Application Range

Specific application range for TSS VARI sc sensors and their connection type.

TSS XL sc Application Range

Specific application range for TSS XL sc sensors and their connection type.

Titanium Sensors Application Range

Application range for Titanium sensors for aggressive media.

Installation

Basin Sensor Installation Overview

Provides a general guide to installing the sensor in a basin.

Pipe Installation Options

Describes various methods for installing the sensor in pipe systems.

Connecting the Sensor Cable

Instructions for properly connecting the sensor cable to the controller.

Operation

Sensor Setup Procedure

Steps for configuring sensor parameters and naming.

Sensor Setup Configuration

Detailed configuration options for sensor parameters like WIPE and CALIBRATE.

Sensor Setup Details

Details configuration settings for name, units, parameters, intervals, and response time.

Calibration Procedures

Instructions for calibrating the sensor for turbidity and solid matter.

Turbidity Calibration

Procedure for calibrating the turbidity measurement.

Maintenance

Troubleshooting

Error Messages Explained

Lists common error messages and their causes and resolutions.

Warnings Explained

Lists common warning messages and their causes and resolutions.

Hach TSS sc Specifications

General IconGeneral
BrandHach
ModelTSS sc
CategoryTest Equipment
LanguageEnglish

Related product manuals