Temporary overrides
Override until the next program step
In auto mode, the current temperature set-point
can be modified.
Press key 5
+ or - to increase or decrease the
displayed set-point.
The set-point temperature flashes and the
override is valid until the next program step.
During the override period, the current set-point
temperature flashes.
Temporary override
In auto mode, this function allows temporary
modification of the ambient temperature, at
any time, whatever the instruction in progress.
The range of duration of this function is from
15 minutes to 12 hours.
Press key 3
, the duration adjusted in PA:1
flashes.
Press key 5
+ or - to adjust the desired duration.
Confirm using the
OK key.
Press key 5
+ or - to adjust the desired
temperature.
Confirm using the
OK key.
The end time of the temporary override flashes on
the bar chart of the screen and the value of the
duration of the temporary override is displayed
in place of the current time, until the return to
automatic mode.
If a temporary override is in progress, it is possible
to modify the temperature in steps of 0.5 °C using
key 5
+ or - .
One press on key 3
allows the delay time to be
modified; the last selected duration is displayed.
What to do if... ?
The symbol is displayed:
change the batteries (2 alkaline batteries of type
LR03 1.5V) as soon as possible.
That heating will not start:
the receiver is not powered, check the fuse and the
circuit breaker.
The heating does not start up, even though the
ambient temperature is less than the set point :
function of the evolution of the ambient
temperature over the last few hours.
The thermostat estimates that the temperature will
be obtained without contributing additional energy.
It does not request ignition of the generator.
Ask your installer for confirmation.
The heating starts up even though the ambient
temperature is greater than the set point
temperature:
Your installer has selected a form of regulation
known as PID which anticipates a drop in the
ambient temperature as a function of its evolution
over the last few hours.
The thermostat estimates that the ambient
temperature will be less than the setpoint
temperature if it does not contribute additional
energy. It requests ignition of the generator.
Ask your installer for confirmation.
The receiver is out of range of the transmitter,
move it suciently close to the receiver.
The receiver does not recognise the
transmitters code :
reconfigure the receiver.
The receiver does not recognise the
transmitters code :
reconfigure the receiver.
The application does not start or does not stop:
The receiver or transmitter is in an area disturbed
by radio emissions (amateur radio, television, GSM
network etc.), move the receiver or transmitter from
the disturbed area.
If the problem persists, contact your
electrician.
Creation of a personalised program P4
This program allows you to adjust the heating to
suit your way of life.
A 24-hour profile is composed of 48 points
(representing the set-points). You can visualise the
composition of your program at the bottom of the
display. 1 program step = 30 minutes.
30 min.
in Eco
30 min.
in Comfort
30 min. in
Comfort 2
Example : creating a program, P4, for a group of
days (5 weekdays + 2 weekend days).
For the 5 weekdays, we would like 3 Comfort
periods from 06:00 to 08:00, from 12:00 to 14:00
and from 18:00 to 22:00.
For the two weekend days, we would like a
Comfort period from 08:00 to 19:00, then a
Comfort 2 period from 19:30 to 22:00.
Press key 1
menu to place the cursor under
prog. The indicators for the seven days of the
week flash.
Press key 5
+ to select to aect the group
of five days (the group of five days flashes).
Confirm using the
OK key.
P1 flashes. Press key 5 + to select P4 (P4
flashes). Confirm using the
OK key.
Press key 1
until 6:00 appears and then key
2
until 8:00 appears.
Then press key 1
until 12:00 and key 2
until 14:00.
Then press key 1
until 18:00 appears and
finally key 2
until 22:00.
If you make an error, press key 5
- to move
backwards or key 5
+ to advance and correct
your programming.
• Confirm using the
OK key.
The group of 2 weekend days flashes.
Confirm using the
OK key.
P1 flashes, press key 5 + to select P4 (P4
flashes). Confirm using the
OK key.
Press key 1
until 8:00 appears and then
key 2
until 19:30 appears.
Next, press key 3
until 22:00 and key 1
until 24:00.
Confirm using the
OK key.
Note:
The latest P4 program is held in memory and
automatically oered to be assigned to a new day
or group of days (whose P4 is empty).
Setting anticipation to 1 sends program P4
=> P4A.
If the anticipation function (
1H, 2H or 3H) in Installer
Parameter PA9 has been confirmed,
P4A is displayed
in place of
P4.
During programming, proceed in the same
way as for P4 knowing that the thermostat will
automatically apply the anticipation with the
duration set in PA:9. It is not useful to foresee
this anticipation time during your programming.
Correct Disposal of This product
(Waste Electrical & Electronic
Equipment)
(Applicable in the European Union and other
European countries with separate collection
systems).
This marking shown on the product or its literature
indicates that it hould not be disposed with other
household wasted at the end of its working life. To
prevent possible harm to the environment or human
health from uncontrolled waste disposal, please
separate this from other types of wastes and
recycle it responsibly to promote the sustainable
reuse of material resources.
Household users should contact either the retailer
where they purchased this product, or their local
government office, for details of where and how
they can take this item for environmentally safe
recycling.
Business users should contact their supplier and
check the terms and conditions of the purchase
contract. This product should not be mixed with
other commercial wastes of disposal.
Usable throughout Europe
å
and in Switzerland
Hager Controls hereby declares that
the EK560 complies with the essential
requirements and other relevant provisions
of Directive 2014/53/EU.
The CE declaration is available on the:
www.hagergroup.com
6
06.2017
6LE001012C
Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com

Related product manuals