104
Super Match 
Item                                                                       Model
AD09SS1ERA(N)
Function ——
Cooling Heating
capacity W 2700 2800
sensible heat ratio W
0.71 /
Dehumidifying capacity 10-³xm³/h
1.0 
indoor unit
power supply
1PH, 220-230V~, 50Hz
Fan
Type × Number ——
centrifugal*1
Speed(H-M-L) r/min
850/750/650
Fan motor output/input power W 11/15
Air-ows (H/M/L) m³/h
530/460/390
Heat exchanger
Type / Diameter mm
inner grooved pipe/
¢
7.0
Row ——
2
Total area m²
0.11
Temp.scope
℃
2.0-7.0
Dimension 
(LxWxH)
External mmxmmxmm
850x420x185
Package mmxmmxmm
1045x540x270
Drainage pipe (material,I.D/O.D)
/
mm
PVC  27/31
control type(Remote/Wired) Remote or Wired
Fresh air hole dimension
/
mm
none
Electricity Heater kW
none
Noise level(H-M-L)
Sound power level dB(A)
43/39/36
Sound pressure level dB(A)
33/29/26
weight(Net/Shipping) kg/kg
17.5/22.5
Piping
Refrigerant
Type 
R410A 
Pipe
Liquid mm
Φ6.35(1/4)
Gas mm
Φ9.52(3/8)
Connecting method
Flared
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB 
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB 
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a 
sound pressure noise level.