Indoor Unit
55
Super Match
2.2 Specication
   Item                                                                          Model AC12CS1ERA(S)/1U12BS3ERA
Function cooling heating
Capacity KW 3.5(0.9~4.5) 3.9(1~4.8)
Sensible heat ratio 0.71 /
Total power input KW 1.03(0.28~1.8) 1.02(0.28~1.8)
Max. power input W 1800 1800
EER or COP W/W 3.39  3.81 
Dehumidifying capacity 10
‐
³×m³/h 1.6
Power cable H05RN-F 4G 4.0mm2 
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 5.0(1.2-8.0)/8.0 4.9(1.2-8.0)/8.0
Start Current A 3
Indoor unit
Unit model (color) AC12CS1ERA(S)
Fan 
Type × Number CENTRIFUGALX2
Speed(H-M-L) r/min 1100/1025/825
Fan motor output/ input power W 30/79
Air-ow(H-M-L) m³/h 650/550/450
Heat 
exchanger 
 Type / Diameter mm inner grooved pipe/φ7.0
Row 3
Total Area m² /
Dimension
External
(
L×W×H
)
mm×mm×mm 990/655/199
Package
(
L×W×H
)
mm×mm×mm 1150/750/300
Drainage pipe  (material , I.D./O.D.) mm PVC  18/20
Controller 
(O-Optional,S-Standard)
Wired  YR-E16(O)/YR-E17(O)
Infrared YR-HD01(S)
Fresh air hole dimension mm NONE
Electricity Heater  kW NONE
Sound power  Noise level (H-M-L) dB(A) 58
Sound pressure Noise level (H-M-L) dB(A) 45/41/36
Pipe
Liquid Pipe(mm)
6.35
Gas   Pipe(mm)
9.52
Connecting Method
ared
Weight             (Net / Shipping) kg / kg 26.3/32.3
cooling Pdesignc(kW)
:
3.5kW SEER/CLASS 6.1/A++ QCE(Annual electricity consumption for cooling) kWh
:
222
heating
 Average Pdesignh(-10
℃
)  3.4kW SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating) kWh
:
1427
Warmer Pdesignh(2
℃
)  3.7kW SCOP/CLASS 4.0/A+ QHE(Annual electricity consumption for heating) kWh
:
1307
Colder Pdesignh(-22
℃
)  / SCOP/CLASS / QHE(Annual electricity consumption for heating) kWh
:
/
Tdesignh
:
-10
℃
Tbivalent
:
-8
℃
TOL
:
-15
℃
Elbu:0
Max. cooling 
condition
Indoor temperature
: 
32
℃
/23
℃
Max. heating condition
 Indoor   temperature
:
27
℃
/-
℃
Outdoor temperature
: 
46
℃
/-
℃
 Outdoor temperature
:
24
℃
/18
℃
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB 
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB 
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a 
sound pressure noise level.