Outdoor Unit
219
Super Match
Item Model 1U24GS1ERA
Power cable H05RN-F 4G  6.0mm2
Communication cable/Connecting cable H05RN-F 4G 2.5mm2
Power source N, V, Hz 1PH,220-230VAC,50/60HZ
Start Current A 3
3
Outdoor 
unit
Unit model (color) 1U24GS1ERA(WHITE)
Compressor
Model / Manufacture SNB130FGYM2/SNB130FGYMC-L1
(
MGC
)
Oil model FV50S
Oil type PVE
Oil charging 500CC
Type Rotary
Fan
Type × Number axial×1
Speed r/min 950/830/750/700/500420/300
Fan motor output/input 
power pow
W 97/70
Air-ow(H-M-L) m³/h 3000
Heat 
exchanger
Type / Diameter mm TP2M/Φ7.9
Row / Fin pitch 2/1.65
Dimension
External
(
L×W×H
)
mm×mm×mm 860/308/730
Package
(
L×W×H
)
mm×mm×mm 995x420x815
Drainage pipe (material , I.D./O.D.) mm /
Refrigerant control method mm/mm 1.8mmEEV+Φ3.0*Φ1.8*200mmCapillary
Defrosting AUTO
Volume of Accumulator L NONE
 Sound power  Noise level       (H-M-L) dB(A) 70
 Sound pressure Noise level       (H-M-L) dB(A) 57
Type of Four way valve SHF-4-10A
material of reduce noise felt
crankcase heater power W /
Weight             (Net / Shipping) kg / kg 49/52
PIPING
Refrigerant
Type / Charge g R410A/1600
Maximum pipe length without 
recharge refrigerant
m
7
GWP 2088
Recharge quantity g/m 45
Pipe
Liquid mm 9.52
Gas mm 15.88
Connecting Method Flared
Between I.D 
&O.D
MAX.Drop m 15
MAX.Piping length m 25
Working  
temp.
Cooling(Min-Max)
O
C -10~46
Heating(Min-Max)
O
C -15~24
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB 
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB 
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound 
intensity meter. It is a sound pressure noise level. 
1. Specication