Indoor Unit
13
Super Match
Item Model AB12CS1ERA
S
Function cooling heating
Capacity KW 3.50
0.9
4.5
3.7
1
4.8
Sensible heat ratio 0.71 /
Total power input KW 1.06(0.28~1.8) 0.99(0.28~1.8)
Max. power input W 1800 1800
EER or COP W/W 3.31 3.71
Dehumidifying capacity 10
³×m³/h 1.5
Power cable H05RN-F 4G 4.0mm2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 5.0(1.2-8.0)/8.0 4.7(1.2-8.0)/8.0
Start Current A 3
Indoor unit
Unit model (color) AB12CS1ERA(S)
Fan
Type × Number CENTRIFUGALX1
Speed(H-M-L) r/min 690/560/520
Fan motor output/ input power W 11/30
Air-ow(H-M-L) m³/h 620/520/450
Heat
exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area /
Dimension
External
L×W×H
mm×mm×mm 570×570×260
Package
L×W×H
mm×mm×mm 718×680×380
Drainage pipe (material , I.D./O.D.) mm PVC 26/32
Controller
(O-Optional,S-Standard)
Wired YR-E16A(O)/YR-E17(O)
Infrared YR-HD01(S)
Fresh air hole dimension mm 95
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 50
Sound pressure Noise level (H-M-L) dB(A) 40/36/32
Panel
Model PB-700IB
External dimensions(W/D/H) mm 700/700/60
Shipping dimensions(W/D/H) mm 740/750/115
Net weight/Shipping weight kg 2.8/4.8
Weight (Net / Shipping) kg / kg 18.5/22
PIPING
Refrigerant
Type / Refrigerant load in factory g R410A/1200
Recharge quantity g/m 45
Max. pipe length without charge
refriigerant
m 5
Pipe
Liquid mm 6.35
Gas mm 9.52
Between I.D
&O.D
MAX.Drop m 10
MAX.Piping length m 15
Coling Pdesignc(kW)
3.5Kw SEER/CLASS 6.1/A++
QCE (Annual electricity consumption for cooling)
kWh
222
heating
Average Pdesignh(-10
) 3.4Kw SCOP/CLASS 3.8/A
QHE (Annual electricity consumption for heating)
kWh
1427
Warmer Pdesignh(2
) 3.7Kw SCOP/CLASS 4.0/A+
QHE (Annual electricity consumption for heating)
kWh
1307
Colder Pdesignh(-22
) / SCOP/CLASS /
QHE (Annual electricity consumption for heating)
kWh
/
Tdesignh
-10
Tbivalent
-8
TOL
-15
Elbu:0
Max. cooling
condition
Indoor temperature
32
/23
Max. heating condition
Indoor temperature
27
/-
Outdoor temperature
46
/-
Outdoor temperature
24
/18
Norminal condition: indoor temperature (cooling): 27
DB/19
WB, indoor temperature (heating): 20
DB
Outdoor temperature(cooling): 35
DB/24
WB, outdoor temperature(heating): 7
DB/6
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter.
It is a sound pressure noise level.