Indoor Unit
15
Super Match
Item Model AB18CS1ERA(S)
Function cooling heating
Capacity KW 5(1.8~5.8) 5.2(2~6.5)
Sensible heat ratio 0.71 /
Total power input KW 1.53(0.55~2) 1.52(0.6~2)
Max. power input W 2000 2000
EER or COP W/W 3.26 3.42
Dehumidifying capacity 10
‐
³×m³/h 1.5
Power cable H05RN-F 4G 4.0mm2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 6.8(2.3-9.5)/9.5 6.7(2.3-9.5)/9.5
Start Current A 3
Indoor unit
Unit model (color) AB18CS1ERA(S)
Fan
Type × Number CENTRIFUGALX1
Speed(H-M-L) r/min 795/690/550
Fan motor output/ input power W 14/40
Air-ow(H-M-L) m³/h 700/620/500
Heat
exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area m² 1.25
Dimension
External
(
L×W×H
)
mm×mm×mm 570×570×260
Package
(
L×W×H
)
mm×mm×mm 718×680×380
Drainage pipe (material , I.D./O.D.) mm PVC 26/32
Controller
(O-Optional,S-Standard)
Wired YR-E16A(O)/YR-E17(O)
Infrared YR-HD01(S)
Fresh air hole dimension mm 95
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 55
Sound pressure Noise level (H-M-L) dB(A) 42/37/35
Weight (Net / Shipping) kg / kg 18.5/22
Panel
Model PB-700IB
External dimensions(W/D/H) mm 700/700/60
Shipping dimensions(W/D/H) mm 740/750/115
Net weight/Shipping weight kg 2.8/4.8
PIPING
Refrigerant
Type / Refrigerant load in factory g R410A/1300
Recharge quantity g/m 45
Max. pipe length without charge refriigerant m 5
Pipe
Liquid mm 6.35
Gas mm 12.7
Between
I.D &O.D
MAX.Drop m 15
MAX.Piping length m 25
Cooling Pdesignc(kW)
:
5.0kW SEER/CLASS 5.1/A QCE(Annual electricity consumption for cooling) 363kWh
heating
Average Pdesignh(-10
℃
) 4.7kW SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating) 1932kWh
Warmer Pdesignh(2
℃
) 5.4kW SCOP/CLASS 4.1/A+ QHE(Annual electricity consumption for heating) 1845kWh
Colder Pdesignh(-22
℃
) / SCOP/CLASS / QHE(Annual electricity consumption for heating) /
Tdesignh
:
-10
℃
Tbivalent
:
-8
℃
TOL
:
-15
℃
Elbu:0
Max. cooling condition
Indoor temperature
:
32
℃
/23
℃
Max. heating condition
Indoor temperature
:
27
℃
/-
℃
Outdoor temperature
:
46
℃
/-
℃
Outdoor temperature
:
24
℃
/18
℃
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound
pressure noise level.