Indoor Unit
17
Super Match
Item Model AB24ES1ERA(S)/1U24GS1ERA
Function cooling heating
Capacity KW 7.1(2~7.3) 7.1(2.5~8)
Sensible heat ratio 0.72 /
Total power input KW 2.20(0.5~2.6) 1.91(0.5~2.6)
Max. power input W 2600 2600
EER or COP W/W 3.23 3.72
Dehumidifying capacity 10
‐
³×m³/h 2.5
Power cable H05RN-F 4G 4.0mm2
Power source N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 9.4(2.3-12)/12 9.0(2.3-12)/12
Start Current A 3
Indoor unit
Unit model (color) AB24ES1ERA(S)
Fan
Type × Number CENTRIFUGALX1
Speed(H-M-L) r/min 670/550/460
Fan motor output/ input power W 38/133
Air-ow(H-M-L) m³/h 1300/1100/870
Heat
exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area m² /
Dimension
External
(
L×W×H
)
mm×mm×mm 840/840/240
Package
(
L×W×H
)
mm×mm×mm 930/930/330
Drainage pipe (material , I.D./O.D.) mm PVC 26/32
Controller
(O-Optional,S-Standard)
Wired YR-E16A(O)/YR-E17(O)
Infrared YR-HD01(S)
Fresh air hole dimension mm 95
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 59
Sound pressure Noise level (H-M-L) dB(A) 46/44/39
Weight (Net / Shipping) kg / kg 25.5/30.5
Panel
Model PB-950JB
External dimensions(W/D/H) mm 950/950/60
Shipping dimensions(W/D/H) mm 985/985/115
Net weight/Shipping weight kg 6.0/7.5
PIPING
Refrigerant
Type / Refrigerant load in factory g R410A/1600
Recharge quantity g/m 45
Max. pipe length without charge refriigerant m 7
Pipe
Liquid mm 6.35
Gas mm 9.52
Between
I.D &O.D
MAX.Drop m 15
MAX.Piping length m 25
Cooling Pdesignc(kW)
:
7.1Kw SEER/CLASS 6.1/A++ QCE(Annual electricity consumption for cooling) 435kWh
Heating
Average Pdesignh(-10
℃
) 5.2Kw SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating) 2044
Warmer Pdesignh(2
℃
) 6.1Kw SCOP/CLASS 4.8/A++ QHE(Annual electricity consumption for heating) 1783
Colder Pdesignh(-22
℃
) / SCOP/CLASS / QHE(Annual electricity consumption for heating) /
Tdesignh
:
-10
℃
Tbivalent
:
-8
℃
TOL
:
-15
℃
Elbu:0
Max. cooling
condition
Indoor temperature
:
32
℃
/23
℃
Max. heating condition
Indoor temperature
:
27
℃
/-
℃
Outdoor temperature
:
46
℃
/-
℃
Outdoor temperature
:
24
℃
/18
℃
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound
pressure noise level.