Indoor Unit
19
Super Match
Item Model AB28ES1ERA(S)/1U28GS2ERA(S)
Function cooling heating
Capacity kW 7.8(2.2-9.5) 8.5(2.5-10.0)
Sensible heat ratio 0.74
Total power input kW 2.43(0.5-4.2) 2.49(0.5-4.2)
Max. power input W 4200 4200
EER or COP W/W 3.21 3.41
Dehumidifying capacity 10
‐
³×m³/h 3.8
Power cable /
Power source(indoor unit) N, V, Hz
1PH, 220-230V~, 50/60Hz
Running /Max.Running current A / A 10.8
(
2.3-14.3)/14.3 10.5(2.3-14.3)/14.3
Start Current A 5
Indoor unit
Unit model (color) AB28ES1ERA(S)
Fan
Type × Number CENTRIFUGALX1
Speed(H-M-L) r/min 670±40/550±50/460±50
Fan motor output / input power W
55/140
Air-ow(H-M-L) m³/h 1300/1100/870
Heat exchanger
Type / Diameter mm inner grooved pipe/φ7.0
Row 2
Total Area m² /
Dimension
External
(
L×W×H
)
mm×mm×mm 840/840/240
Package
(
L×W×H
)
mm×mm×mm 930/930/330
Drainage pipe (material , I.D./O.D.) mm
PVC 26/32
Controller
(O-Optional,S-Standard)
Wired YR-E17(O) OR YR-E16A(O)
Infrared YR-HD01(S)
Fresh air hole dimension mm /
Electricity Heater kW NONE
Sound power Noise level (H-M-L) dB(A) 59
Sound pressure Noise level (H-M-L) dB(A) 46/44/39
Weight (Net / Shipping) kg / kg 25.5/30.5
Panel
Model PB-950JB
External dimensions(W/D/H) mm .950/950/60
Shipping dimensions(W/D/H) mm 985/985/115
Net weight/Shipping weight kg
6.0/7.5
PIPING
Refrigerant
Type / Refrigerant load in factory g R410A/2000
Recharge quantity g/m 45
Max. pipe length without charge
refriigerant
20
Pipe
Liquid mm 9.52
Gas mm 15.88
Between I.D &O.D
MAX.Drop m
15
MAX.Piping length m
25
cooling Pdesignc(kW)
:
7.8Kw SEER/CLASS 5.1/A QCE(Annual electricity consumption for cooling)kWh
:
530
heating
Average Pdesignh(-10
℃
) 7.2Kw SCOP/CLASS 3.8/A QHE(Annual electricity consumption for heating)kWh
:
2653
Warmer Pdesignh(2
℃
) 8.3Kw SCOP/CLASS 5.0/A++ QHE(Annual electricity consumption for heating)kWh
:
2509
Colder Pdesignh(-22
℃
) / SCOP/CLASS / QHE(Annual electricity consumption for heating)kWh
:
/
Tdesignh
:
-10
℃
Tbivalent
:
-8
℃
TOL
:
-15
℃
Elbu:0
Max. cooling
condition
Indoor temperature
:
32
℃
/23
℃
Max. heating condition
Indoor temperature
:
27
℃
/-
℃
Outdoor temperature
:
46
℃
/-
℃
Outdoor temperature
:
24
℃
/18
℃
Norminal condition: indoor temperature (cooling): 27
℃
DB/19
℃
WB, indoor temperature (heating): 20
℃
DB
Outdoor temperature(cooling): 35
℃
DB/24
℃
WB, outdoor temperature(heating): 7
℃
DB/6
℃
WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound
pressure noise level.