Loading...
Electic Control and
Debugging
381
Super Match
Outdoor
LED
display
Error code discription
Wired controller
display(Hex-YR-
E17)---for duct/
cassette
Wired controller
display(Decimal-
YR-E16/YR-E16A)---
for duct/cassette
Panel
display(Hex)--
-for round way
cassette
34
Malfunction of gas pipe temp. sensor
for indoor unit C
36 54 36
35
Malfunction of gas pipe temp. sensor
for indoor unit D
37 55 37
36
Malfunction of gas pipe temp. sensor
for indoor unit E
38 56 38
38
Malfunction of module temp.sensor
Momentary power failure detection
3A 58 3A
39 Malfunction of condensing temp. sensor 3B 59 3B
40
Malfunction of liquid pipe temp. sensor
for indoor unit E
3C 60 3C
41 Malfunction of ‘Toci’temp. sensor 3D 61 3D
42 System high pressure switch off 3E 62 3E
43 System low pressure switch off 3F 63 3F
44
System high pressure protection.
Refrigerant overabundance,high
condensing temp. or malfunction of fan
motor.
40 64 40
45
System low pressure protection.
Refrigerant shortage,low defrosting
temp., or malfunction of fan motor.
41 65 41