Indoor Unit
95
Super Match
3. Drilling the holes and attaching the suspension bolts
(1) Drill 25mm holes at the suspension-bolt locations. The two special nuts
are provided with the unit. The M1O nut must be obtained locally.
(2) Install the bolts, then temporarily attach Special nuts A and B and a
normal M1O nut to each bolt.
Bo/t strength: 980 to 1470 N (100 TO 150 kgf)
If using anchor bolts
(1) Drill holes for anchor bolts at the locations at which you will set the suspension bolts. Note that anchor bolts
must be obtained locally.
(2) Install the anchor bolts, then temporarily attach special nut ”B” (included) and a locally-procured M1O nut to
each of the bolts.
Anchor-bolt strength: 980 to 1470 N (100 TO 150 kgf)
4. Installing the indoor unit
(1) Lift unit so that suspension bolts pass through suspension ttings at the
sides (four places),and slide the unit back.
(2) Fasten the indoor unit into place by tightening-up the special ”B” bolts and
the M10 nuts. Make sure that unit is secure and will not shift back and forth.
For half-concealed installation
When installing the indoor unit in a semi-concealed orientation, make sure to
reinforce the insulation of the unit on all sides. Drops of water may fall from the
unit if it is not thoroughly insulated.
CAUTION
In order to check the drainage, be sure to use a level during installation of the
indoor unit. If the installation site of the indoor unit is not level, water leakage
may occur.
5. Installing the coupler heat insulation
After checking for gas leaks, insulate by wrapping insulation around the two parts (large and small) of the indoor
unit coupling, using the coupler heat insulation. After installing, the coupler heat insulation, wrap both ends with
vinyl tape so that there is no gap. Secure both ends of the heat insulation material using nylon fasteners.
When using an auxiliary pipe, make sure that the fastener used is insulated in the same way.
Note:
When installing the unit on the oor, x the four rubber base feet in the accessories on the bottom plate of the unit
with four 4x16 screws and 4 at washers, as the position in the gure.