Haier AU05IFPERA - [113] Protection of Overload; [114] Voltage too Low of DC Bus Line of Transducer

Haier AU05IFPERA
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
No
No
No
No
Yes
Yes
Yes
Yes
Check if voltage of power supply is normal
Check if wire of electric box is correct
Improve power supply circuit
Correct the wiring due to diagram
Replace compressor
Replace power module
If compressor is normal
(compressor coil resistor, insulation)
Compress load too much,
check the reason
If power module is normal
[113] Protection of overload
[114] Voltage too low of DC bus line of transducer
Check if voltage of power
supply is normal
Measure if DC bus line
voltage between P and N of
module is less than 375V
Circuit of DC bus line voltage on
inverter control board abnormal,
replace inverter control board
If AC contactor or relay acts well
Improve power supply circuit
Adjust or replace relay
Correct the wiring due to diagram
Check if wire of electric box
is correct
Check rectier, reactor, electrolytic
capacitor in inverter main circuit
No
Yes
Yes
Yes
Yes
No
No
No