OPERATION
This hood has an automatic operation system (see para-
graph "Automatic operation (sensor)”).
Calibration occurs automatically each time the hood is re-
connected to the electrical network (e.g.: the first time it is
installed after a blackout). It can also be done manually
(see paragraph "Adjusting the parameters for automatic
operation-Manual adjustment").
During calibration, which lasts for 5 minutes, the controls
will flash and only the lights button can be used.
Control panel
To select the hood functions, simply touch the controls.
T1 = Motor OFF key (stand by)
T2 = Speed selection key (extraction power) low. The key
flashes if delayed hood switch-off is activated (only for
models with remote control).
T3 = Speed selection key (extraction power) medium. The
key flashes if delayed hood switch-off is activated (only for
models with remote control).
T4 = Speed selection key (extraction power) high. The key
flashes if delayed hood switch-off is activated (only for
models with remote control).
T5 = Speed selection key (suction power) intensive - it
lasts 5 minutes after which it switches back to medium
speed (extraction power) or it switches off if delayed hood
switch-off is activated (only for models with remote control).
The key flashes in both cases to indicate the speed timer.
T6 = Light ON/OFF key. Short press to switch illumination
of the cooking hob on or off.
T7 = Automatic operation (sensor).
Filter saturation indicators (T5)
At regular intervals, the hood signals the need to perform
maintenance on the filters.
Key (T5) on with steady light: the grease filter requires
maintenance.
Key (T5) on with flashing light: the activated carbon filter re-
quires maintenance.
Note: The filter saturation indicator is visible within on first
minute after switching off the hood; the saturation indicat-
ors must be reset within this time.
Resetting the filter saturation indicators (T5)
Press and hold key (T5).
Activating the activated carbon filter saturation indic-
ator (T5).
Note: this operation must be performed with the hood off.
This indicator is normally deactivated; press and hold key
(T5) to activate the function: the key will light up steadily.
To deactivate the function, press and hold key (T5): the
key will start flashing.
Automatic operation (sensor) (T7)
Press key (T7) (the central LED (T7) lights up white). The
hood will switch on at the most suitable speed based on the
fumes detected by the sensor the hood is equipped with.
Adjusting the parameters for automatic operation
Note: All of the calibration, selection, adjustment and lo-
gical connection operations described below are possible
with the hood switched off (OFF).
The parameters are adjusted automatically each time the
hood is reconnected to the mains (e.g. first installation or
after a power failure) or manually.
Manual adjustment
To be performed when automatic operation is unsatisfact-
ory and when normal environmental conditions persist in
the kitchen.
Manual adjustment includes:
• Hood calibration.
• Hob selection (gas - induction or electric).
Hood calibration (T7).
Press and hold key (T7), all of the LEDs of the key will flash
“darker” to indicate that calibration has started; the calibra-
tion process will take about 5 minutes.
Hob selection (gas - induction or electric).
Simultaneously press and hold keys (T2 -T3); keys (T2 - T3
- T4) will start flashing for 5 seconds.
Within this time, press:
key (T2) in the case of a gas hob
key (T3) in the case of an electric hob
key (T4) in the case of an induction hob.
The selected key will remain lit to indicate that a selection
has been made; after 10 seconds, the key will flash briefly
to indicate that the selection made has been recorded.
MAINTENANCE WARNINGS
• Cleaning: For cleaning, simply use a cloth moistened
with neutral liquid detergents. Do not use cleaning tools or
instruments.
• Avoid the use of abrasive products. DO NOT USE ALCO-
HOL!
For product maintenance, see the images at the end
of the installation marked by this symbol.
● Anti-Grease Filter: The metallic anti-grease filter
must be cleaned once a month with non-aggressive deter-
8