Installation
Waiting time
Maintenance-free lubrication oil is located in the 
capsule of the compressor. This oil may get through 
closed pipe system during transportation. Before con-
necting the appliance to the power supply you have to 
wait 2 hours so that the oil runs back into the capsule.
Electrical connection
Aligning the appliance 
The appliance should be placed on a at and solid sur-
face. 
1.  Tilt the appliance slightly backwards.
2.  Set the feet to the desired level. 
Make sure the distance to the wall on the hinge side is 
at least 100mm for the door to open properly. 
3.  The stability can be checked by alternately bump-
ing on the diagonals. The slightly swaying should 
be the same in both directions. Otherwise the 
frame  can  warp;  possible  leaking  door  seals  are 
the result. A lowering of the rear feet facilitates the 
door.
1. 2.
3.
  WARNING!
To avoid risks, a damaged power cord must be replaced by customer services (see war-
ranty card).
Before each connection check if:
 ▶ power supply, socket and fusing are appropriate to the rating plate.
 ▶ the power socket is earthed and no multi-plug or extension is being used. 
 ▶ the power plug and socket are of sound condition.
Connect the plug to a properly installed household socket.
34