Haier air conditioner Edition: 20070116
-24-
2. Rating operating
rating cool:
ķ
a. G code enter condition˖high speed coolˈset temp. is 16ćˈpress temperature “- key and set key
together, enter mode after resound 2 times.
b. then operate as following:
Enter rated frequency operation mode; panel shown cool status; in communication rated shown.
c. Exit condition˖Exit rated operate mode and enter remote control set status after received remote
control signal.
middle capacity:
ĸ
a. G code enter conditions˖High fan cool, set temp. is 16 , press 4 times continuanć tly in 7sˈEnter
rated frequency operation; Panel show cool status; have ration in communication.
Reso Enter rated frequency operation; Panel show cool status; have ration in communication.
Resound 5 times.
b. then operating as following: enter middle capacity rated frequency operating;
c. Exit condition˖Exit rated operate mode and enter remote control set status after received remote
control signal.
min capacity cool
Ĺ ˖
a. G code enters condition: remote control high fan cool, set temp. is 16 , press 8 times continuanć tly
in 7sˈresound 7 times.
b. then operating as following: enter min capacity rated frequency operating; panel show cool status;
have ration in communication.
Enter rated frequency operation; Panel show cool status; have ration in communication.
c. Exit condition˖Exit rated operate mode and
rated heat
ĺ
: rating heat
a. G code enter condition˖high speed coolˈset temp. is 16ćˈpress temperature “- key and set key
together, enter mode after resound 2 times.
b. Then operation as following program:
Panel show heat status; have ration in communication.
Enter rated frequency operation; Panel show cool status; have ration in communication.
c. Exit condition: enter remote control set status after received remote control signel.
middle capacity heat:
Ļ
a. G code enters condition ˖Remote control high fan heat, set temp. is 30.7 , press 4 timesć
continuantly in 7sˈresound 7 times.
b. Then operation as following program: panel show cool status; have ration in communication.
Enter rated frequency operation; Panel show cool status; have ration in communication.
c. Exit condition˖Exit rated operate mode and enter remote control set status after received remote
control signal.
min capacity heat:
ļ
a. G code enters condition˖Remote control high fan heat, set temp. is 30 , press 8 times continuanć tly