6.2.1 Cooling capacity-temperature curves
HSU-09HSA03/R2(DB)
Cooling value - Temperature table
Indoor temp. Outdoor temp. (Humidity 46%)
DB/WB
18ć 20ć 25ć 32ć 35ć 40ć 43ć 46ć
18/12ć
2383 2313 2243 2196 1986 1866 1669 1518
18/14ć
2534 2460 2386 2336 2060 1986 1811 1615
20/15ć
2610 2537 2460 2409 2179 2048 1854 1666
22/16ć
2672 2625 2580 2493 2254 2082 1838 1729
25/18ć
2849 2754 2671 2615 2365 2187 1963 1780
27/19ć
2940 2842 2750 2693 2486 2247 2029 1862
30/22ć
3045 3015 2923 2862 2588 2394 2140 1979
32/23ć
3240 3173 3077 2971 2724 2527 2285 2083
32/24ć
3342 3277 3208 3141 2841 2670 2405 2172