Haier air conditioner Edition: 20070116
-30-
4. Thermistor resistance chart
Room temperature sensor
Temp. (ć) R (KO) Power Input (V)
-20 281.34 0.33
-19 263.56 0.35
-18 247.84 0.37
-17 231.66 0.40
-16 217.35 0.42
-15 204.02 0.45
-14 191.61 0.47
-13 180.04 0.50
-12 169.24 0.53
-11 159.17 0.56
-10 149.77 0.59
-9 140.99 0.62
-8 132.78 0.65
-7 126.11 0.69
-6 117.93 0.73
-5 111.22 0.76
-4 104.93 0.80
-3 98.04 0.84
-2 93.52 0.88
-1 88.35 0.92
0 83.50 0.97
1 78.94 1.01
2 74.67 1.06
3 70.65 1.10
4 66.88 1.15
5 63.33 1.20
6 60.00 1.25
7 56.88 1.00
8 53.91 1.35
9 51.15 1.41
10 48.51 1.46
11 46.04 1.51
12 43.72 1.57
13 41.52 1.63
14 39.45 1.68
15 37.50 1.74
16 35.66 1.80
17 33.92 1.85
18 32.27 1.91