14
Error message Cause Solution
1:
The start indicator wasn't lighted,and the
buzzer sound abnormaly.
Door not shut pr operly. Shut door properly.
2:
The start indicator lighted on 0.2s and
off 0.2s for twice,repeate 4s later .
Drainage error, water has not emptied
within 4 minutes.
Clean the filter (page 15) and check drain
hose for blockages. If pr oblem continues,
contact an appr oved service engineer.
3:
The start indicator lighted on 0.2s and
off 0.2s for 3 times,repeate 4s later .
Temperature sensor is not properly
connected or damaged.
Contact an appr oved service engineer.
4:
The start indicator lighted on 0.2s and
off 0.2s for 4 times,repeate 4s later .
Heating element error, set temperature
is not reached within specifi ed time
(this will be displayed at the end of the
programme).
Contact an appr oved service engineer.
5:
The start indicator lighted on 0.2s and
off 0.2s for 5 times,repeate 4s later .
Correct water level not reached within 8
minutes.
Ensure the tap is fully open and water
pressure is normal. If problem continues,
contact an appr oved service engineer.
6:
The start indicator lighted on 0.2s and
off 0.2s for 6 times,repeate 4s later .
Timer error. Contact an appr oved service engineer.
7:
The start indicator lighted on 0.2s and
off 0.2s for 7 times,repeate 4s later .
Motor overheating. Contact an appr oved service engineer.
8:
The start indicator lighted on 0.2s and
off 0.2s for 8 times,repeate 4s later .
Water overflow. Contact an appr oved service engineer.
Error Signals
The door lock light will flash in different combinations to signal when ther e is an error, see the table below
for the meanings.
Error
Error
Error
Error
Error
Error
Error
Error

Related product manuals