EasyManua.ls Logo

Haier USYM18UCDSA - Troubleshooting & References

Haier USYM18UCDSA
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TROUBLESHOOTING & REFERENCES
J-1
ENGLISH
TROUBLESHOOTING & REFERENCES
Table of Contents
Special Functions ...................................................................................................................................................................J-3
Auto Restart .......................................................................................................................................................................... J-3
Forced Defrost ...................................................................................................................................................................... J-3
Indoor Temperature Display (Highwall Only) ....................................................................................................................... J-3
Enhanced Defrost ................................................................................................................................................................. J-3
Temperature Compensation ................................................................................................................................................ J-4
Matching Tables .....................................................................................................................................................................J-6
Resistance Chart / Sensor Denitions ....................................................................................................................................J-7
Resistance Values ..................................................................................................................................................................J-8
Louver Motors .......................................................................................................................................................................J-8
EEV ........................................................................................................................................................................................J-8
Component Ratings ...............................................................................................................................................................J-9
4-Way Valve ..........................................................................................................................................................................J-9
Basepan Heater ....................................................................................................................................................................J-9
Fan Motors ............................................................................................................................................................................J-9
Refrigeration Diagrams .......................................................................................................................................................J-10
Master Error Code Chart ......................................................................................................................................................J-12
Outdoor Unit Error Codes ....................................................................................................................................................J-16
Temperature Sensor Error Codes ......................................................................................................................................J-16
Pressure-Related Error Codes ...........................................................................................................................................J-17
Communication Error Code ...............................................................................................................................................J-17
Error Codes Caused by Abnormal Refrigerant Circuit Conditions ...................................................................................J-18
Outdoor Error Code Related to Indoor Unit ......................................................................................................................J-18
Error Code Related to the PCB ...........................................................................................................................................J-18
Error Codes Related to the IPM ..........................................................................................................................................J-18
Error Codes Related to Compressor, Outdoor Fan & 4-Way Valve ..................................................................................J-19
Flow Charts .......................................................................................................................................................................... J-20
[1] Outdoor EEPROM Malfunction .....................................................................................................................................J-20
[2] Outdoor IPM over current or short circuit ...................................................................................................................J-20
[4] Communication abnormal between PCB and IPM .......................................................................................................J-21
[6] DC voltage or AC voltage high......................................................................................................................................J-21
[8] Discharge temperature too high protection ................................................................................................................J-22
[9] DC fan motor fault .........................................................................................................................................................J-22
[10] Outdoor defrosting temp. sensor Te abnormal ........................................................................................................J-23
[11] Suction temp.sensor Ts abnormal..............................................................................................................................J-23
[12] Outdoor ambient temp. sensor Ta abnormal ............................................................................................................J-23
[13] Discharging temp. sensor Td abnormal .....................................................................................................................J-23
[15] Communication abnormal between indoor unit and outdoor unit ...........................................................................J-23
[16] Lack of refrigerant or discharging pipe blocked ........................................................................................................J-24
[17] 4-way valve reversing failure ......................................................................................................................................J-24
[18] Compressor motor desynchronizing .........................................................................................................................J-25
[24] Compressor startup failure ........................................................................................................................................J-25
[25] Input overcurrent of the drive module .......................................................................................................................J-25
[42] Open high pressure switch .........................................................................................................................................J-26
[43] Open low pressure switch ........................................................................................................................................... J-26
[44] High pressure detected in system .............................................................................................................................J-27
[45] Low pressure detected in system ..............................................................................................................................J-27

Table of Contents