www.haiwell.com Haiwell PLC - Analog Module User Manual
7 / 18
CR code
Function description
S08AI
S08AO
S08XA
11H
channel 2 input value
channel 2 output value
input channel 2 input value
12H
channel 3 input value
channel 3 output value
input channel 3 input value
13H
channel 4 input value
channel 4 output value
input channel 4 input value
14H
channel 5 input value
channel 5 output value
input channel 1 signal type, note 2
15H
channel 6 input value
channel 6 output value
input channel 2 signal type, note 2
16H
channel 7 input value
channel 7 output value
input channel 3 signal type, note 2
17H
channel 8 input value
channel 8 output value
input channel 4 signal type, note 2
18H
channel 1 signal type, note 2
channel 1 signal type, note 2
Use the engineering value mark, note 6
19H
channel 2 signal type, note 2
channel 2 signal type, note 2
input channel 1 engineering lower limiting value
1AH
channel 3 signal type, note 2
channel 3 signal type, note 2
input channel 2 engineering lower limiting value
1BH
channel 4 signal type, note 2
channel 4 signal type, note 2
input channel 3 engineering lower limiting value
1CH
channel 5 signal type, note 2
channel 5 signal type, note 2
input channel 4 engineering lower limiting value
1DH
channel 6 signal type, note 2
channel 6 signal type, note 2
input channel 1 engineering upper limiting value
1EH
channel 7 signal type, note 2
channel 7 signal type, note 2
input channel 2 engineering upper limiting value
1FH
channel 8 signal type, note 2
channel 8 signal type, note 2
input channel 3 engineering upper limiting value
20H
Use the engineering value mark, note 6
Use the engineering value mark, note 6
input channel 4 engineering upper limiting value
21H
channel 1 engineering lower limiting
value
channel 1 engineering lower limiting
value
input channel 1 sampling frequency, note 1
22H
channel 2 engineering lower limiting
value
channel 2 engineering lower limiting
value
input channel 2 sampling frequency, note 1
23H
channel 3 engineering lower limiting
value
channel 3 engineering lower limiting
value
input channel 3 sampling frequency, note 1
24H
channel 4 engineering lower limiting
value
channel 4 engineering lower limiting
value
input channel 4 sampling frequency, note 1
25H
channel 5 engineering lower limiting
value
channel 5 engineering lower limiting
value
input channel 1 zero point correction value
26H
channel 6 engineering lower limiting
value
channel 6 engineering lower limiting
value
input channel 2 zero point correction value
27H
channel 7 engineering lower limiting
value
channel 7 engineering lower limiting
value
input channel 3 zero point correction value
28H
channel 8 engineering lower limiting
value
channel 8 engineering lower limiting
value
input channel 4 zero point correction value
29H
channel 1 engineering upper limiting
value
channel 1 engineering upper limiting
value
Channel 1~4 input disconnection alarm, note 5
2AH
channel 2 engineering upper limiting
value
channel 2 engineering upper limiting
value
output channel 1 output value
2BH
channel 3 engineering upper limiting
value
channel 3 engineering upper limiting
value
output channel 2 output value
2CH
channel 4 engineering upper limiting
value
channel 4 engineering upper limiting
value
output channel 3 output value
2DH
channel 5 engineering upper limiting
value
channel 5 engineering upper limiting
value
output channel 4 output value
2EH
channel 6 engineering upper limiting
value
channel 6 engineering upper limiting
value
output channel 1 signal type, note 2
2FH
channel 7 engineering upper limiting
value
channel 7 engineering upper limiting
value
output channel 2 signal type, note 2
30H
channel 8 engineering upper limiting
value
channel 8 engineering upper limiting
value
output channel 3 signal type, note 2
31H
channel 1 sampling frequency, note 1
power-off output mark, note 8
output channel 4 signal type, note 2
32H
channel 2 sampling frequency, note 1
channel 1 power-off output value
Use the engineering value mark, note 6
33H
channel 3 sampling frequency, note 1
channel 2 power-off output value
output channel 1 engineering lower limiting value
34H
channel 4 sampling frequency, note 1
channel 3 power-off output value
output channel 2 engineering lower limiting value
35H
channel 5 sampling frequency, note 1
channel 4 power-off output value
output channel 3 engineering lower limiting value
36H
channel 6 sampling frequency, note 1
channel 5 power-off output value
output channel 4 engineering lower limiting value
37H
channel 7 sampling frequency, note 1
channel 6 power-off output value
output channel 1 engineering upper limiting value
38H
channel 8 sampling frequency, note 1
channel 7 power-off output value
output channel 2 engineering upper limiting value
39H
channel 1 zero point correction value
channel 8 power-off output value
output channel 3 engineering upper limiting value
3AH
channel 2 zero point correction value
Channel indicator status, note 7
output channel 4 engineering upper limiting value
3BH
channel 3 zero point correction value
Reserve
power-off output mark, note 8
3CH
channel 4 zero point correction value
output channel 1 power-off output value
3DH
channel 5 zero point correction value
output channel 2 power-off output value
3EH
channel 6 zero point correction value
output channel 3 power-off output value
3FH
channel 7 zero point correction value
output channel 4 power-off output value
40H
channel 8 zero point correction value
output channel indicator, note 7
41H
Channel 1~8 input disconnection alarm,
note 5
Reserve
42H~4FH
Reserve
Note:
1. Sampling frequency:0 - 2 times, 1 - 4 times, 2 - 8 times, 3 - 16 times, 4 - 32 times, 5 - 64 times, 6 - 128 times, 7 - 256 times
2. Signal type: 0 - [4,20]mA, 1 - [0,20]mA, 2 - [1,5]V, 3 - [0,5]V, 4 - [0,10]V, 5 - [-10,10]V
3. Disconnection alarm:Each bit indicates 1 channel, 0-normal, 1-disconnection
4. Use the engineering value mark:Each bit indicates 1 channel, 0-No, 1-Yes
5. Channel indicator status:Each bit indicates 1 channel, 0-off, 1-on
6. Power-off output mark:Each bit indicates 1 channel, 0-No, 1-Yes

Table of Contents

Other manuals for Haiwell PLC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haiwell PLC and is the answer not in the manual?

Haiwell PLC Specifications

General IconGeneral
SeriesHaiwell PLC
Programming LanguageFunction Block Diagram
Communication PortsRS232, RS485, Ethernet
Digital InputsVaries by model (e.g., 8, 16, 32)
Digital OutputsVaries depending on the model (e.g., 8, 16)
Analog InputsVaries by model (e.g., 4, 8)
Analog OutputsVaries by model (e.g., 2, 4)
Power Supply24V DC
Real-Time Clock (RTC)Yes
Expansion ModulesYes, supports various expansion modules for I/O, communication, and special functions
Input Voltage24V DC
Data MemoryVaries depending on the model
Humidity Range5% to 95% (non-condensing)

Related product manuals