27
●TempMode
The displayed temperature can be switched between Celsius and Fahrenheit.
●Sleep
Select whether you will activate the auto sleep function.
●ShutOffSet
Set auto shutoff time.
●AirShutOff
Specify whether or not to enable the function that allows you to force the termination of cooling after
completion of work. Forced termination in high temperature may cause premature failure of the heating
element. Do not use the function except for work in low temperature.
●Preset
Temperature setting can be switched between the normal mode and the preset mode.
If selecting the preset mode, you will be asked for the number of preset to have available for programming.
●TCBAlert
Turns on the TC B alert to stop heater control if the temperature fails to reach the predetermined level
after a specific period of time following the start of control.
The heater power alert function will not operate if the timer is set to "- - -".
●LockMode
Select "ON", "CUSTOM" or "OFF" for password setting. If selecting the "ON", perform the setting for password.
If selecting the "CUSTOM", choose whether or not the password function is needed when moving to the various
setting modes and set the password.
TEMP SET
SEL PRESET
OFFSET SET
FLOW SET
TIMER SET
RAMP SET
PROFILE SET
SEL PROFILE
MODE CHANGE
USB OPE
(Heating temperature setting)
(Selecting the preset number)
(Offset temperature setting)
(Airflow setting)
(Timer setting)
(Temperature rise rate setting)
(Profile settings)
(Selection of profile)
(Changing modes)
(Reading/saving of profile to USB memory device)