Document #101-0204 22 10/21/2011
Additional Wire Terminations For Use With The Credit
Card or Customer Value Card System.
The installation of the machine should proceed as outlined in the above section. However, if a Credit
Card or Customer Value Card System is being used, the following must be performed, as well.
• A Cat 5 or 5E cable should be pulled to each HTK on the site. The
cable should be run from were the connection to the internet device
(router or switch) is located back to the HTK. When crimping Cat 5
or 5E cable consult an electrician or network person for proper attach-
ment.
NOTE: When running Cat 5 or 5E cable, the run should
be with out any splicing or mid point connections. If there are this
can lead to communication issues. The maximum length of a net-
work cable is 328 ft or 100 meters. If longer a switch must be used
to prevent communication issues.
• The Cat 5 or 5E cable can be run in with the low voltage wires coming
from the car wash
Additional Wire Terminations For Use With A Hamilton
Code System or POS 4000
The installation of the machine should proceed as outlined in the above section. However, if a Hamilton
Code System or POS 4000 is being used, the following must be performed, as well.
• A 485 communication line (A. 1 pair, twisted, shielded cable) should
be pulled to each HTK on the site. The cable should be run from were
the connection to the code system device (isolator box) is located back
to the HTK. The connection to the HTK is on a 2 position phoenix
connector located on the bottom side of the controller. Position 1 is the
positive and Position 2 is the negative.
NOTE: When running a 485 communication line, the run
should be made with out any splicing or mid point connections.
If there are this can lead to communication issues. The maximum
length of a 485 cable is 1000 ft.
• The 485 communication can be run in with low voltage wires coming
from the car wash.