TROUBLESHOOTING FOR STANDARD BILL OPERATION (continued)
ERROR PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION
8.0 Low magnetics
Rejected bill
Bill not touching heads
These errors can be
displayed intermittently on
bill rejects. This is a normal
condition.
If you continuously get
these errors with total
reject condition, check
rollers to ensure a good,
flat contacting point
between head and roller is
established.
Return for Service
8.1 Short bill
The bill inserted was too
short
J Jammed bill
Will be displayed for 2
minutes if the obstruction
is not removed. After the
2 minutes, either a 1.7 or
1.8 will be displayed for the
blocked sensor.
Remove obstruction, clean
sensor, cycle power, reset
controller
P
Tokenote® programming
All switches are turned ON
Turn switches back to
normal positions
VII. ERROR CODES