EasyManua.ls Logo

Hanna Instruments HI 221 - User Manual

Hanna Instruments HI 221
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Instruction Manual
HI 221 HI 223
pH/mV/ºC
Bench Meters
with Calibration Check
www.hannainst.com
Manufacturer since 1978
Functions
pH Calibration
HI 223 Calibration Check
Microprocessor pH Meter
Confirm
2
Buffer
nd
CFM
Select 2
Buffer
nd
/
Confirm
1 Buffer
st
CFM
/
Select 1
Buffer
st
Start Calibration
CAL
CFM
/GLP
Show GLP Information
Set Instrument Parameters
Clear Log/Cal Information
SET/CLR
RCL
Recall Log Information
LOG
Store Log Information
Select pH/ORP
RANGE
RCL
LOG
CLR
SET
C
C
RANGE
GLP
CFM
CAL
C
ATC
pH
SLOW
FAST
POOR
GOOD
Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 221 and is the answer not in the manual?

Hanna Instruments HI 221 Specifications

General IconGeneral
pH Resolution0.01 pH
pH Accuracy±0.01 pH
TypepH Meter
pH Range-2.00 to 16.00 pH
mV Range±2000 mV
mV Resolution0.1 mV
mV Accuracy±0.2 mV
Temperature Resolution0.1°C
Temperature Accuracy±0.5°C
Temperature CompensationAutomatic or manual
Input Impedance10¹² Ohms

Summary

Warranty Information

Instrument Overview

Preliminary Examination

Steps to inspect the instrument after unpacking to ensure no damage occurred during shipping.

General Description

Provides a general overview of the HI 221 and HI 223 bench meters and their features.

Functional Description

Front Panel Layout

Details the components and controls on the front panel of the instrument.

Rear Panel Connectors

Identifies and describes the connectors and ports located on the rear panel.

Specifications

HI 221 Specifications

Lists the technical specifications for the HI 221 pH meter model.

HI 223 Specifications

Lists the technical specifications for the HI 223 pH meter model.

Operational Guide

Power and Probe Connections

Instructions for connecting power supply and electrode/probe assemblies.

Instrument Start-up Procedure

Steps for powering on the instrument and its initial self-test sequence.

pH Measurement Process

Detailed steps for performing accurate pH measurements after proper calibration.

ORP Measurement Process

Guide on how to conduct Oxidation-Reduction Potential (ORP) measurements.

Taking Temperature Measurements

Procedure for measuring temperature using the dedicated temperature probe.

pH Calibration

Calibration Preparation

Steps for preparing buffer solutions and the instrument for calibration.

Two-Point Calibration Procedure

Step-by-step instructions for performing a standard two-point pH calibration.

One-Point Calibration Procedure

Steps for conducting a single-point pH calibration when appropriate.

Calibration Messages and Diagnostics

Error Messages Explained

Interpretation of various error messages encountered during calibration.

Warning Messages Explained

Understanding warning messages related to calibration quality and electrode condition.

Electrode Condition and Response

How to interpret the electrode condition and response time gauges.

Data Logging and GLP

Good Laboratory Practice (GLP) Features

Overview of GLP functions for data storage and retrieval of calibration status.

Logging Current Data

Instructions on how to store current measurement data into the instrument's memory.

Viewing Logged Data

Procedure for retrieving and reviewing previously logged data records.

Deleting Logged Data

Steps for removing logged data records or entire dates from memory.

Instrument Setup and Configuration

Setup Mode Parameters

Explains how to enter and navigate the instrument's setup menu for configuration.

Calibration Alarm Time-Out Setting

How to configure the time-out period for calibration reminders.

Instrument ID Configuration

Procedure to set and manage the instrument's unique identification number.

Time and Date Settings

Steps for setting the current time and date on the instrument.

pH Resolution Setting (HI 223)

How to adjust the pH measurement resolution for the HI 223 model.

Beep Status Configuration

How to enable or disable the audible beep feedback for key presses.

Serial Communication Settings

How to configure baud rate and command prefix for serial data transfer.

Technical Calibration Procedures

Temperature Calibration

Detailed procedure for calibrating the instrument's temperature sensor.

mV Calibration Procedure

Step-by-step guide for recalibrating the mV measurement function.

PC Interface and Commands

Connecting to a PC

Instructions on how to connect the instrument to a computer for data transfer.

Sending Commands from PC

How to control the instrument remotely via a PC terminal program.

Simple Instrument Commands

Lists basic commands for instrument control and data retrieval.

Commands Requiring Instrument Response

Lists commands that query the instrument and expect a data response.

Electrode Conditioning and Maintenance

Electrode Preparation

Initial steps for handling electrodes, including removing protective caps and checking for air bubbles.

Electrode Storage Guidelines

Best practices for storing electrodes to maintain their performance and longevity.

Periodic Electrode Maintenance

Routine inspection and upkeep procedures for electrodes and their cables.

Electrode Cleaning Procedures

Detailed methods for cleaning electrodes using specialized cleaning solutions.

Troubleshooting Guide

Addressing Slow Response or Drift

Solutions for issues related to slow electrode response or signal drift.

Resolving Noisy or Fluctuating Readings

Steps to troubleshoot and eliminate noise or fluctuations in measurements.

Troubleshooting Calibration Errors

Solutions for common calibration failures and incorrect readings.

Handling Instrument Error Messages

Guidance on interpreting and resolving general "Err xx" error messages.

Accessories and Recommendations

pH Calibration Solutions

Lists the available pH buffer solutions for calibration purposes.

Electrode Storage and Cleaning Solutions

Lists solutions for storing and cleaning the instrument's electrodes.

Refill Electrolyte Solutions

Lists electrolyte solutions required for refilling refillable electrodes.

pH Electrode Models

Details various pH electrode types and their specific applications.

Other Instrument Accessories

Lists additional accessories such as adapters, simulators, and software.

User Recommendations and Safety

Important advice for users regarding safe operation and environmental considerations.